Generation | New Features | eFPGASIM version |
---|---|---|
Gen5 |
| 2.7+ Beta 3.X |
Gen4 |
| 2.X - 3.X |
Gen3 |
| 1.X Deprecated in 2.0 |
...
Version | Features | Limitations |
---|---|---|
From | Gate Control | The Polarity parameter CANNOT be assigned to Low. Only active high is supported at the moment. |
eHS Naming Limitations
As per
Jira Legacy | ||||||
---|---|---|---|---|---|---|
|
Field | Limitations |
---|---|
Schematic Editor - names of components | in names of in/outputs, “/” are transformed into “-” from Simulink’s side. |
eHS OpalBoards block - block name | a clear error is seen on build whenever a character is used in the eHS block name that is not alphanumeric or in the list seen above (space, underscore, etc). I would call this limitation already documented, since the error is already well-reported and points the user to the problem reasonably well. |
eHS SFunction block - block name | error is seen on build if the name of an eHS block contains an odd number of (“) double quote characters. |
Aside from the special cases mentioned above, these fields seem to work for all UTF-8 characters (models build, load and run).