The multiphase load can represent a 1, 2, or 3-phase load. Thus, there are three types of loads in this library as follows:

...

  • To set the active power of phase 1: loadID/P1

  • To set the reactive power of phase 1: loadID/Q1

Single Phase ZIP Load

Parameters

Symbol

Description

Unit

ID

Load name

a unique name

Status

Connect/Disconnect status

Initial value 1 (0 for disconnected)

V (kV)

Nominal voltage (phase-to-phase)

kV

Bandwidth* (pu)

Cut-off voltage to convert to Z load

p.u.

Conn. type

Connection type

‘wye’ for Yg

‘delta’ for Delta

K_z*

Constant impedance percentage

p.u.


K_i*

Constant current percentage


K_p*

Constant power percentage


Use initial volt­age?

Determines if the assigned power is based on nominal or initial voltage (from page Bus)

0: nominal voltage

1: initial voltage

Bus1

Name of phase 1 of the connected bus

a unique name


P1 (kW)

Active power phase 1

kW

Q1 (kVAr)

Reactive power phase 1

kVAr

Two Phase ZIP Load

Parameters

Symbol

Description

Unit

ID

Load name

a unique name

Status

Connect/Disconnect status

Initial value 1 (0 for disconnected)

V (kV)

Nominal voltage (phase-to-phase)

kV

Bandwidth* (pu)

Cut-off voltage to convert to Z load

p.u.

Conn. type

Connection type

‘wye’ for Yg

‘delta’ for Delta

K_z*

Constant impedance percentage

p.u.


K_i*

Constant current percentage


K_p*

Constant power percentage


Use initial volt­age?

Determines if the assigned power is based on nominal or initial voltage (from page Bus)

0: nominal voltage

1: initial voltage

Bus1

Name of phase 1 of the connected bus

a unique name


Bus2

Name of phase 2 of the connected bus

P1 (kW)

Active power phase 1

kW

Q1 (kVAr)

Reactive power phase 1

kVAr

P2 (kW)

Active power phase 2

kW

Q2 (kVAr)

Reactive power phase 2

kVAr

Three Phase ZIP Load

Parameters

Symbol

Description

Unit

ID

Load name

a unique name

Status

Connect/Disconnect status

Initial value 1 (0 for disconnected)

V (kV)

Nominal voltage (phase-to-phase)

kV

Bandwidth* (pu)

Cut-off voltage to convert to Z load

p.u.

Conn. type

Connection type

‘wye’ for Yg

‘delta’ for Delta

K_z*

Constant impedance percentage

p.u.


K_i*

Constant current percentage


K_p*

Constant power percentage


Use initial volt­age?

Determines if the assigned power is based on nominal or initial voltage (from page Bus)

0: nominal voltage

1: initial voltage

Bus1

Name of phase 1 of the connected bus

a unique name


Bus2

Name of phase 2 of the connected bus

Bus3

Name of phase 3 of the connected bus

P1 (kW)

Active power phase 1

kW

Q1 (kVAr)

Reactive power phase 1

kVAr

P2 (kW)

Active power phase 2

kW

Q2 (kVAr)

Reactive power phase 2

kVAr

P3 (kW)

Active power phase 3

kW

Q3 (kVAr)

Reactive power phase 3

kVAr

...