The ACIM machine model and its associated Hardware Configurations have been archived.  If starting a new project, consider using the SCIM Machine Model instead.

...

Channel Name

Type

Units

Default Value

Description

EnableInput
0

Set this channel to one of the following values:

  • 0 - Disables the machine model.
  • 1 - Enables the machine model.
Load TorqueInputNewton Meters0NmTorque applied to the shaft of the machine.
Rotor TemperatureInputKelvin298.15KTemperature of the motor rotor. If this value is greater than 0, Temperature Correction is performed for the Stator Resistance and the Rotor Resistance.
Stator TemperatureInputKelvin298.15KTemperature of the motor stator. If this value is greater than 0, Temperature Correction is performed for the Stator Resistance and the Rotor Resistance.
VaOutputVolts0VPhase A voltage of the electric motor.
VbOutputVolts0VPhase B voltage of the electric motor.
VcOutputVolts0VPhase C voltage of the electric motor.
IaOutputAmperes0APhase A current of the electric motor.
IbOutputAmperes0APhase B current of the electric motor.
IcOutputAmperes0APhase C current of the electric motor.
Electromagnetic TorqueOutputNewton Meters0NmElectromagnetic torque of the electric motor.
SpeedOutputRPM0RPMRotor speed of the electric motor.
PositionOutputRadians0radRotor position of the electric motor.

...