Info |
---|
Notes
|
1. Import of Export Definition
...
Activate the project in the Data Manager.
Open project in PowerFactory main window.
Run a positive sequence AC Load Flow.
...
Select “File” -> “Export” -> “DGS Format...”
Configure the following settings in the DGS-Export dialog:
General:
DGS Version: V7.00
Format: XML File
Encoding: UTF-8 (with BOM)
File Name: as you wish (e.g. Your Model.xml)
Selection:
Variable Sets: OPAL-RT UDB Export Definition (from step 1.)
Base Selection: All elements of the active project
...
...
Start export by clicking on “Execute”.
Note |
---|
Verify and ensure there is absolutely no error or warning reported in PowerFactory's Output window regarding this process. |
3. ePHASORSIM Solver Configuration
...