Model name | GHOST microgrid wireframe | ||
---|---|---|---|
Highlights |
Known distributed energy resources benchmark originally published by the MIT and NREL. This version covers only the wireframe and excludes DERs, breakers, controllers microgrid controller and protection relays. | ||
Model diagram | |||
Single-phase nodes | 605 | ||
States (L, C, ...) | 301 | ||
Sources (3φ) | 1 | Machines | 2 |
Transformers (3φ) | 27 | ||
Lines (coupled RL) | 41 | ||
Induction motors | 2 | ||
Loads (3φ) | 39 | ||
Hardware | OP5707XG
| ||
Software |
| ||
Minimum license required | FXG Max (1 core) | ||
Results |
* Performance under transient conditions varying considerably depending on the study type, this benchmark measures the minimum achievable time-step without overruns in steady-state conditions. A rule of thumb is to consider 10 to 20 % buffer time for calculations under transient conditions. | ||
Benchmark | |||
Performance comparison between new (OP5707XG) and previous (OP5700) hardware generations | |||
...