Page Content
Table of Contents | ||
---|---|---|
|
Connecting Cables
These are the basic cabling instructions for your OP4610XG. Use the cables provided to connect your devices, as instructed.
Connect the power cord to the unit and to the appropriate power source (outlet).
Connect DB37 cables from OP4610XG to external devices (motor, controller, etc.).
Before connecting the cables, make sure that the amplitudes are compatible with OPAL-RT DB37 amplitudes (see OP4610XG Simulator Specifications).
Connect the I/O expansion cables from OP4610XG to external devices if applicable.
Cables used depends on I/O expansion option.
Make sure that all cables are properly connected before powering up.
Make sure to provide all adequate and necessary ventilation.
Power up the unit using the main power switch.
Connecting the Ground Screw
You must connect a grounding cable from the OP4610XG ground screw to the rack to ensure that the OP4610XG terminates securely in a ground.
Proper grounding helps prevent electric shocks, protects the simulator from voltage spikes (from a variety of causes, including lightening strikes), and provides increased immunity from EMI by lowering noise levels and emissions.
Select a flat braided grounding strap of adequate length (as short as possible to provide the best protection), with ring terminals on each end.
Attach one ring terminal to the ground screw on the OP4610XG.
...
Attach the other ring terminal to the rack using a nut and lock washer.