Table-top Use
Make sure to provide all adequate and necessary ventilation (at least 10 cm or 4 inches) at the front (cooling air intake) and the rear (cooling air exhaust) of the unit.
Rack Mount
The OP48xx-IO FPGA processor and expansion unit can be installed directly in a 19'' rack.
Normally, the rack mount brackets and handles are assembled to the chassis.
Expand |
---|
title | 🔴 If brackets and handles are delivered as a separate kit, follow this procedure to assemble the mounting brackets with handles to the expansion unit. |
---|
|
Hardware ListThe hardware for the rack mount brackets and handles are provided in a plastic bag. 2x 2U Rack Mount Brackets 2x Pull Handles Black Anodized Aluminum 8-32 x 3" 4x T00-6800 Black SS Phillips Flat Head Screws 8-32 X ½" long 8x T00-1402 Black, SS, Phillips Flat Head Screws 6-32 x 5/16" long Image Added
AssemblingFollow these simple steps to install the brackets and the handles. For each side: Remove the two (2) top front screws. Image AddedAssemble each rack mount bracket using 4 screws. Do not use the screws you removed in the previous steps, they are too short. 4 screws per bracket, 6-32 x 5/16" flat head, Phillips, OPAL-RT P/N T00-1402 Image Added
Assemble the handle to the bracket using two (2) screws. 2 screws per handle, 8-32 x ½" flat head, Phillips, OPAL-RT P/N T00-6800. Image Added
|
Connecting the Cables
These are the basic cabling instructions for your OP4810-IO and OP4815-IO. Use the cables provided to connect your devices, as instructed.
...