Table-top Use

Make sure to provide all adequate and necessary ventilation (at least 10 cm or 4 inches) at the front (cooling air intake) and the rear (cooling air exhaust) of the unit.

Rack Mount

The OP48xx-IO FPGA processor and expansion unit can be installed directly in a 19'' rack.
Normally, the rack mount brackets and handles are assembled to the chassis.

Expand
title🔴 If brackets and handles are delivered as a separate kit, follow this procedure to assemble the mounting brackets with handles to the expansion unit.

Hardware List

The hardware for the rack mount brackets and handles are provided in a plastic bag.

  • 2x 2U Rack Mount Brackets 

  • 2x Pull Handles Black Anodized Aluminum 8-32 x 3"

  • 4x T00-6800 Black SS Phillips Flat Head Screws 8-32 X ½" long

  • 8x T00-1402 Black, SS, Phillips Flat Head Screws 6-32 x 5/16" long

    Image Added

Assembling

Follow these simple steps to install the brackets and the handles.
For each side:

  • Remove the two (2) top front screws.

    • Put the screws away, they will be replaced with longer ones.

    Image Added
  • Assemble each rack mount bracket using 4 screws.

    • Do not use the screws you removed in the previous steps, they are too short.

    • 4 screws per bracket, 6-32 x 5/16" flat head, Phillips, OPAL-RT P/N T00-1402

      Image Added
  • Assemble the handle to the bracket using two (2) screws.

  • 2 screws per handle, 8-32 x ½" flat head, Phillips, OPAL-RT P/N T00-6800.

    Image Added

Connecting the Cables

These are the basic cabling instructions for your OP4810-IO and OP4815-IO. Use the cables provided to connect your devices, as instructed.

...