EFSNITT-788: When the Reset Models Channel is asserted, the models are reset and placed into a paused state but some outputs of the models retain their last valid value (instead of going back to 0)
EFSNITT-828: When using VeriStand 2019 R3 and the RT-Linux Image 2022 Q4 on the deployment target, the project will hang on deployment with certain VeriStand Simulation Model files. The Power Electronics Add-on is not the root cause, but it exacerbates the problem. It is recommended to either upgrade your version of VeriStand to 2020 R6 or VeriStand 2021, or if using VeriStand 2019 R3 use the RT Linux Image 2022 Q3 instead.
PEATT-990: The Encoder and Hall Effect sensor signals generated by the second machine of the PMSM BLDC model are not transmitted to their respective VeriStand channels. The signals work as expected when mapped to the Digital Output channels