The Power, 3-ph component computes the mean value of the instantaneous active power P (in watts) and reactive power Q (in vars) associated with a periodic set of three-phase voltages and currents over a running window of one cycle of the specified fundamental frequency.

The output signal Q is accurate only for balanced and harmonic-free three-phase voltages and currents.

The output is held constant to the specified Initial active power and Initial reactive power values for one cycle of the specified fundamental frequency.

Symbol

Mask Parameters

NameDescriptionUnitVariable = {Possible Values}
DescriptionUse this field to add all kinds of information about the component
Description = {'string'}
Fundamental frequencyFundamental frequency used for the calculation of the active power (P) and the reactive power (Q). This value cannot be modified during the simulationHzFnom = { [0, 1e12] }
Initial active power
Initial active power value of the magnitude of the output signal for the first simulation cycle. This value cannot be modified during the simulationWPmean_init = { [-1e64 1e64] }
Initial reactive power
Initial reactive power value of the magnitude of the output signal for the first simulation cycle. This value cannot be modified during the simulationVarQmean_init = { [-1e64 1e64] }

...