Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Description

Controlled I Source, 1-ph

The controlled  current sources, 1-ph represent a single-phase A.C. source with a series or parallel RLC impedance. In the network, these sources only generate the signal received on the control connectors. Hence, this process serves only to amplify or inject a signal in the network.


Panel
borderColor#627781
titleColor#627781
borderWidth1
borderStylesolid
titleTable of Contents

Table of Contents
indent20px
stylecircle


Current sources have parallel impedance only that can be series of parallel RLC elements. 

Current sources inject current between buses without grounding.

Image Added

Mask and Parameters




RLC connection type

 Series (series R, L, C) or parallel (parallel R, L, C).


RResistance value.ohms
LInductance value.H
CCapacitor value/F

Ports, Inputs, Outputs and Signals Available for Monitoring

Ports

  • The current source injects a current from one bus (port) to another (port), without grounding.

Inputs

  • I input (current source): The current amplitude signal.

Outputs

  • None

Sensors

  • I_label: Current signal (current source) (A).