Notes

  • ePHASORSIM has currently the following limitations for the import of PowerFactory models:

    • Only positive sequence simulation and positive sequence components as described in Native Library section are supported.

    • Only a subset of the PowerFactory components are supported by the import. Please refer to the Specs for DGS File Format for a full list.

    • Only dynamic controllers from the PSS/e E compatible library (v2022 or 2019) are supported. DIgSILENT or IEEE , CGMES, IEEE or other category of controllers are not supported.

  • This guide has been tested with PowerFactory version 2019 SP1 and 2023.

1. Import of

...

“Export Definition”

  1. Open the Data MangerManager.

  2. Right-click on the Project -> “Import”.

  3. Select “

    View file
    nameOPAL-RT UDB Export Definition.pfd
    ” -> “Open”. (for

    1. For PowerFactory versions 2019 and earlier use

      View file
      nameOPAL-RT UDB Export Definition v19.pfd

    )
  4. Optionally select a new destination path via “New Path” in your Data Manager:

    • As this Export Definition is equal for all projects, it can be imported outside of your PowerFactory project.

      Image RemovedImage Added
  5. Click “OK” to import the export definition

  6. Afterwards a new folder should appear in the project structure

...

  1. Select “File” -> “Export” -> “DGS Format...”

    Image RemovedImage Added

  2. Configure the following settings in the DGS-Export dialog:

    • General tab:

      • DGS Version: V5 V7.00

      • Format: XML File

      • Encoding: UTF-8 (with BOM) (not an option in PowerFactory 2019)

      • File Name: as you wish (e.g. Your Model.xml)

      • Variable Sets: OPAL-RT UDB Export Definition (from step 1) (only in 2019 version)

        powerfactory - Remote Desktop Connection.pngImage Added
    • Selection tab (not an option in PowerFactory 2019):

      • Variable Sets: OPAL-RT UDB Export Definition (from step 1.)image-20240325-145656.pngImage Removed ) (only in 2021 and higher versions)

      • Base Selection: All elements of the active project

    powerfactory - Remote Desktop Connection.pngImage RemovedImage RemovedImage Added