Mask and Parameters
General
Name | Description | Unit | Variable = {Possible Values} |
---|---|---|---|
Vmin | Forward voltage drop | V | {[0,1e12]} |
Ropen | Open state resistance | Ohm | {(0,1e12]} |
Rclose | Closed state resistance | Ohm | {(0,1e12]} |
Rsnubber | Snubber resistance | Ohm | {(0,1e12]} |
Csnubber | Snubber capacitance | F | {[0,1e12]} |
Control type | External Input pins: Schematic control signal; the received integer is converted to a binary string where each digit corresponds to a phase External Input sensors: Target digital inputs |
Advanced
Name | Description | Unit | Variable = {Possible Values} | |
---|---|---|---|---|
Fail reset | Fail reset | {Enable, Disable} | ||
Precision valve | Enable: Enables recalculation of the state switch command using exact time between steps (as percentage of time step) Disable: does not use precision valve | {Enable, Disable} | ||
Imin | Holding current | A | {[0,1e12]} | |
Tq | Thyristor turn off time | s | {[0,1e12]} | |
Fbov | Forward break over voltage | V | {[0,1e12]} | |
Rbov | Reverse break over voltage | V | {[0,1e12]} |
Ports, Inputs, Outputs and Signals Available for Monitoring
Ports
Name | Description |
---|---|
Net_1 | Network connection |
Net_2 | Network connection |
Inputs
Name | Description |
---|---|
D | Delay used for precision valves |
P | Binary coded firing pulses |
Outputs
None
Sensors
Name | Description | Unit |
---|---|---|
D | Delay used for precision valve, measured from changing point to current time step | s |
P | Binary coded firing pulses | |
FailSig | Fail reset signal | |
I | Diode current | A |
Isw | Switch current | A |
Delay | Delay due to forward voltage drop | s |
Delay12 | Delay in forward Thyristor mode | s |
Delay21 | Delay in anti parallel Thyristor mode | s |
DelayExt12 | Delay for external trigger | s |
DelayExt21 | Delay for external trigger | s |
Cmd12 | Forward Signal state command | |
Cmd21 | Anti parallel Signal state command | |
CmdExt12 | Signal state external command | |
CmdExt21 | Signal state external command | |
State12 | Forward Thyristor state | |
State21 | Anti-parallel Thyristor state |
Note that in the previous table, the suffixes "12" and "21" denote the forward (positive to negative) and anti-parallel (negative to positive) thyristor states respectively. One can identify the positive terminal of the device as the one closest to the input pin. So, in the default (not flipped or rotated) thyristor back-to-back icon, the positive terminal is the top one.