Page Content
...
Name | Description | Unit |
---|---|---|
P | Positive sequence active power evaluated using positive sequence voltage and current followed by a low-pass filter | pu |
Q | Positive sequence reactive power evaluated using positive sequence voltage and current followed by a low pass filter | pu |
PF | Power factor evaluation using active and reactive power | - |
Vg | Three-phase instantaneous grid voltages | pu |
Vrms | RMS value of the three-phase grid voltages | pu |
Ig | Three-phase instantaneous grid currents | pu |
Vdc_pu | Nominal DC link voltage | pu |
Vrms_avg | Average of the RMS value of three-phase grid voltages | pu |
Freq | Frequency of the three-phase grid voltage obtained from PLL | Hz |
wt | Angle varying between 0 and 2*pi, synchronized on zero crossings of the fundamental (positive-sequence) of phase A voltage | rad |
Limitations
Currently, the Signal Conditioning Block only supports three-phase balanced voltages and currents.
Intellectual Property Disclaimer
...