The Modbus master Master I/O interface allows connecting to various Modbus slaves and send read/write commands. The interface can operate over TCP/IP using an Ethernet physical link or over RTU using a serial link (RS232/RS485). Using a standard network interface card, the Modbus TCP protocol can be easily and rapidly integrated into any simulation model. With the proper user configuration, a driver is initialized on the target simulator at the start of the simulation and connects with all configured slave devices to begin data transmission. |
Cfm tabs page | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||
Modbus is a data communications protocol originally published by Modicon (now Schneider Electric) in 1979 for use with its programmable logic controllers (PLCs). Modbus has become a de facto standard communication protocol and is now a commonly available means of connecting industrial electronic devices. It is widely used for Industrial Automation and Energy system applications. |
Software Platform Compatibility
Auibutton | |||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Auibutton | |||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||
Auibutton | |||||||||||||||||||||||||||||
|
Auibutton | |||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Product Selection Guide
Modbus TCP, RTU or ASCII require software license OP3262license OP3262, which comes with 50 data points (visit . Visit this page more information on data points).
If additional data points are required, then they may be added via product OP3050 product OP3050.
Modbus TCP
Modbus TCP can be added to real-time simulators without the need of for additional hardware.
However, since real-time simulators come with at least one available ethernet Ethernet port, if additional physical ethernet Ethernet ports are required on the real-time simulator, these can be added via a kit.
Note that for applications requiring many ethernet Ethernet ports,the OP4510 platform is and OP4512 simulators are not recommended.
Modbus RTU
For Modbus RTU, applications requiring RS-232 are supported natively by real-time simulators with one serial port.
If RS-485 or additional RS-232 ports are required, then a BLG-series Bluestorm PCI module OP3310 PCIe serial card must be added to the system. Due to the form factor of the Bluestorm modules, they are only compatible with OP5600, OP5700 and OP5000-series simulators. Hence, for applications requiring RS-485 or multiple RS-232 ports, the OP4500-series platform is not recommended
The OP3310 PCIe serial card 16 ports is not compatible with the OP4510, OP4512 and OP4610XG simulators.
Modbus ASCII
Modbus ASCII applications require the use of an external gateway (EKI-1221-CE) to convert Modbus TCP to Modbus ASCII.
Type | Description | Product Number |
---|
Optional
Description
Simulator Compatibility
Additional requirement(s)
OP4510-series
OP5600-series
OP5700-series
OP5000-series
Software
OP3262
Simulator Compatibility | ||||
---|---|---|---|---|
OP4510v2 | OP5033XG | OP5600v2 | OP5700 | |
Driver | Driver license for Modbus Master protocol using TCP-IP, RTU or ASCII interfaces |
. 50 I/O data points are included. |
For additional data points |
Software
OP3050-1000
OP3050-5000
OP3050-30000
, add OP3050 (see below). | OP3262 | YES | YES | YES | YES | ||
Additional data points | License for additional I/O data points for Ethernet-based communication protocols. |
---|
1,000, 5,000, or 30,000 (unlimited) data points may be added. |
License OP3262 is required. | OP3050-1000 | YES | YES | YES | YES | |
Add-on module |
---|
OP3821
Dual-port |
PCIe X1 Gigabit Ethernet Kit for |
OP4xxx Series of Real-Time Simulators*. Can be added if more physical |
Ethernet ports are required |
. | OP3821 | OP4510v2 | ||||
OP3821-4610 | OP4610XG | |||||
---|---|---|---|---|---|---|
Add-on module |
I350T4V2BLK
Intel I350T4V2 Quad Port Ethernet Server Adapter 10/100/1000 Mbps for OP5xxx Series of Real-Time Simulators*. Can be added if more physical |
Ethernet ports are required |
Add-on module
BLG005-01
BlueStorm PCIe 8 ports RS-232/422/485, surge suppression, External DB-9 I/O Box
Open PCI slot required
External hardware
for Modbus ACII
. | I350T4V2BLK | YES | YES | YES | ||
Add-on module |
---|
BLG039-03
BlueStorm PCI 8 ports RS422/485, surge suppression, External DB-9 I/O Box. Can be used for Modbus RTU over RS-485.
Open PCI slot required
Add-on module
BLG043-01
BlueStorm PCI, 4 ports RS232 and 4 ports RS422/485, with DB9 cable. Can be used for Modbus RTU over RS232 and/or RS485.
Open PCI slot required
Add-on module
BLG006-01
BlueStorm PCIe 16 ports RS232/422/485. Bidirectional data speeds up to 1.8432 Mbps (RS-422/485). Hardware selectable RS-232/422/485. Default configuration: 16 ports RS-232. Any other configuration must be requested by the customer as it requires jumper settings before installing the board in the system. FCC certified and CE marked
Can be used for Modbus RTU over RS232 and/or RS485.
Open PCI slot required
Serial Board 8-port RS-232/422/485 PCIe - Low Profile for XG Series. Includes: 1x Cable SCSI VHDCI 68 male to 8-port DB9 Male Connector*. | OP3310-08-K1 | OP4610XG | YES | YES | YES | |||||||
Add-on module | Serial Board 16-port RS-232/422/485 PCIe. Includes: 2x Cable SCSI VHDCI 68 male to 8-port DB9 Male Connector*. | OP3310-16-K1 | YES | YES | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Add-on module | Serial Board 16-port RS-232/422/485 PCIe. Includes: 2x Cable SCSI VHDCI 68 male to 8-port DB9 Male Connector*. | OP3310-16-K2 | YES | |||||||||
Add-on module | Modbus Gateway 1-port. Uses to convert Modbus between ASCII and TCP modes. |
|
|
|
|
| YES | YES | YES | YES |
* Available PCIe slot required. Note that OP4510 and OP4512 simulators only have one PCIe slot.