This section includes the following custom device channels. The value of an input channel can be modified dynamically at execution time.
Channel Name | Type | Default Value | Description |
---|---|---|---|
Scenario ID | Input | 0 | Specifies the index of the scenario to be simulated. Modify the value of this channel at run-time to switch between scenarios. This channel is only available when Use Scenarios? is enabled. |
...
The eHS solver is available in various form factors. Each form factor provides different capabilities for the number of Sources, Switches, Measurements, and Passive Elements that can be simulated.
Features | eHSx16 | eHSx32 | eHSx64 | eHSx128 |
---|---|---|---|---|
Number of Sources | 16 | 32 | 64 | 128 |
Number of Switches |
12 | 48 | 72 | 144 | |
Number of Measurements | 16 | 32 | 64 | 128 |
Number of Resistors | Unlimited | |||
LCA |
Capability* | Yes | |||
Estimated |
Maximum Number of |
States** | 84 | 112 | 168 | 344 |
Supported Switch Types | IGBT/Diode, Diode, Breaker, Thyristor, Ideal Switch. See Supported Circuit Editors for complete list. | |||
Supported Non- |
Switching Devices | Resistor, Inductor, Capacitor, Ideal Transformer, Mutual inductance, PI Line. See Supported Circuit Editors for complete list. | |||
Calculation |
Power (GFLOPS) | 6.4 | 12.8 | 25.6 | 51.2 |
Maximum |
Number of Scenarios | Up to 512. Limit depends on circuit complexity. |
* LCA, or Loss Compensation Algorithm, optimizes losses for standard topologies such as 2-level converter and NPC 3-level converter arms.