Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

This section includes the following custom device channels. The value of an input channel can be modified dynamically at execution time.

Channel Name

Type

Default Value

Description

Scenario ID

Input

0

Specifies the index of the scenario to be simulated. Modify the value of this channel at run-time to switch between scenarios.

This channel is only available when Use Scenarios? is enabled.

...

The eHS solver is available in various form factors. Each form factor provides different capabilities for the number of Sources, Switches, Measurements, and Passive Elements that can be simulated.

Features

eHSx16

eHSx32

eHSx64

eHSx128

Number of Sources

16

32

64

128

Number of Switches

24

12

48

72

144

Number of Measurements

16

32

64

128

Number of Resistors

Unlimited

LCA

capability

Capability*

Yes

Estimated

maximum number

Maximum Number of

states

States**

84

112

168

344

Switches type supported

Supported Switch Types

IGBT/Diode, Diode, Breaker, Thyristor, Ideal Switch. See Supported Circuit Editors for complete list.

Supported Non-

switching devices supported

Switching Devices

Resistor, Inductor, Capacitor, Ideal Transformer, Mutual inductance, PI Line. See Supported Circuit Editors for complete list.

Calculation

power

Power (GFLOPS)

6.4

12.8 

25.6

51.2

Maximum

number

Number of Scenarios

Up to 512. Limit depends on circuit complexity.

* LCA, or Loss Compensation Algorithm, optimizes losses for standard topologies such as 2-level converter and NPC 3-level converter arms.
** The maximum number of states also depends on the number of inputs and outputs. There is no hard coded limit.

...