Table of Contents |
---|
This block allows you to interface with the OP8110 amplifier groups. A group is defined as a collection of three amplifiers, e.g 1-2-3 or 4-5-6. This block can also be used to set the modes of each amplifier in a group and apply gain and offset calibration parameters (set at 1 and 0 respectively by default).
...
Name | Description |
---|---|
GUI_In | This input is used to communicate with the GUI in the console. |
Amp x Enable | This input activates the amplifier X output when the AMPLIFIER X ENABLE MODE is selected to MODEL OUTPUT ENABLE. The input is active high. |
Amp x Vref | This input is used to pass the voltage output reference to amplifier X. The value directly corresponds to the output voltage of the amplifier (with respect to the phase neutral). If the amplifier group operates in DIFFERENTIAL mode, this input corresponds to the output voltage between amplifier phase L1 and amplifier phase L2. For details of maximum voltages possible in each mode, please consult OP8110 4Q Power Amplifier in Specialized Solutions Documentation. |
SFP to OpInput | The user must connect an OpInput block with the tag SFP00 (or SFP01 for the second unit and so on). This port is used to establish communication with the amplifier. The process of mapping the amplifier bitstream I/O with the model I/O tags is provided in Simulator SFP Communication Setup. |
Outputs
Name | Description |
---|---|
GUI_out | This output is used to communicate with the GUI in the console |
Global Status | This port outputs the global status of the amplifier group. |
Amp 1 Status | This pin outputs the status of amplifier 1. |
Amp 1 Measure | This pin provides the measurements from amplifier 1. It includes the measurements of the following values:
|
Amp 2 Status | This port outputs the status of amplifier 2. |
Amp 2 Measure | This port provides the measurements from amplifier 2. It includes the measurements of the following values:
|
Amp 3 Status | This port outputs the status of amplifier 3. |
Amp 3 Measure | This port provides the measurements from amplifier 2. It includes the measurements of the following values:
|
SFP to OpOutput | The user must connect an OpOutput block with the tag SFP00 (or SFP01 for the second unit and so on). This port is used to establish communication with the amplifier. The process of mapping the amplifier bitstream I/O with the model I/O tags is provided in Simulator SFP Communication Setup |