Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Page Content

Table of Contents
minLevel1
maxLevel6
include
outlinefalse
indent
excludePage Content|Have a question or need help?
typelist
class
printablefalse

Have a question or need help? 

Auibutton
externalUrlhttps://www.opal-rt.com/contact-sales-team/
color#F4F5F6
filterSpacefalse
iconfa-user
destinationexternalUrl
textColorPaletteDefault
typeprimary
titleGet in touch
textColor#091E42
url
targettrue
selectedUrlhttps://www.opal-rt.com/contact-sales-team/
an.spaceKeyCPM
idjhp17cghey
backgroundColorPaletteDefault

Solution

Cfm tabs page
colorPalettesDefault
tabsPageTitleSummary
primaryTabtrue
color#0052CC
idnl7uiehq977
backgroundColorPaletteDefault

The C37.118 Master driver allows the simulator to connect to one or many Phasor Measurements Units (PMUs), typically operating as C37.118 Slaves to stream phasor data. The simulator connects with the PMU, requests the configuration and sends a command to begin the data transmission. The received data is available for computation and analysis within the simulation model. The C37.118 communication protocol has been implemented according to the IEEE Std C37.118.2-2011 standard. Three communication protocols are supported: TCP only, UDP only or TCP/UDP.

Cfm tabs page
colorPalettesDefault
tabsPageTitleAbout IEEE C37.118
color#0052CC
id48yzumbkxsi
backgroundColorPaletteDefault

C37.118 is the IEEE Standard for Synchrophasor Measurements for Power Systems, which defines synchrophasors, frequency, and rate of change of frequency (ROCOF) measurement under all operating conditions. It specifies methods for evaluating these measurements and requirements for compliance with the standard under both steady-state and dynamic conditions.


Software Platform Compatibility

Auibutton
externalUrlhttps://opal-rt.atlassian.net/wiki/spaces/PRD/pages/143823297/C37.118+Master
color#F4F5F6
filterSpacefalse
iconatlaskit-DocumentIcon
destinationexternalUrl
textColorPaletteDefault
typeprimary
titleIEEE C37.118 Master documentation for RT-LAB
textColor#091E42
targettrue
selectedUrlhttps://opal-rt.atlassian.net/wiki/spaces/PRD/pages/143823297/C37.118+Master
an.spaceKeyCPM
id8uosgsjhczg
backgroundColorPaletteDefault
Auibutton
externalUrlhttps://opal-rt.atlassian.net/wiki/spaces/PDOCHS/pages/149259469/C37.118+Master
color#F4F5F6
filterSpacefalse
iconatlaskit-DocumentIcon
destinationexternalUrl
textColorPaletteDefault
typeprimary
titleIEEE C37.118 Master documentation for HYPERSIM
textColor#091E42
targettrue
selectedUrlhttps://opal-rt.atlassian.net/wiki/spaces/PDOCHS/pages/149259469/C37.118+Master
an.spaceKeyCPM
idij3hl3gi2wr
backgroundColorPaletteDefault

Product Selection Guide

C37.118 Master requires software license OP3272, which comes with 50 data points. Visit this page more information on data points.
If additional data points are required, then they may be added via product OP3050

Since real-time simulators come with one available Ethernet port, if additional physical Ethernet ports are required on the real-time simulator, these can be added via a kit.
Note that for applications requiring many Ethernet ports,the OP4510 and OP4512 simulators are not recommended.

C37.118 Master can be added to real-time simulators without the need for additional hardware.

A time synchronization module to maintain high-precision sync and time-stamping may be required depending on the application. For more information on precision timing, please this page: Precision Timing Synchronization.

Type

Description

Product Number

Simulator Compatibility

OP4510v2
OP4512
OP4610XG

OP5033XG

OP5600v2
OP5650

OP5700
OP5705XG
OP5707XG

Driver

Driver license for C37.118 Master protocol for PMU interface and synchrophasor communication. 50 I/O data points are included. For additional data points, add OP3050 (see below).

OP3272

YES

YES

YES

YES

Status
colourRed
titleOptional

Additional data points

License for additional I/O data points for Ethernet-based communication protocols. 1,000, 5,000, or 30,000 (unlimited) data points may be added. License OP3272 is required.

OP3050-1000
OP3050-5000
OP3050-30000

YES

YES

YES

YES

Status
colourRed
titleOptional

Add-on module

Dual-port PCIe X1 Gigabit Ethernet Kit for OP4xxx Series of Real-Time Simulators*. Can be added if more physical Ethernet ports are required.

OP3821

OP4510v2
OP4512

OP3821-4610

OP4610XG

Status
colourRed
titleOptional

Add-on module

Intel I350T4V2 Quad Port Ethernet Server Adapter 10/100/1000 Mbps for OP5xxx Series of Real-Time Simulators*. Can be added if more physical Ethernet ports are required.

I350T4V2BLK

YES

YES

YES

Status
colourRed
titleOptional

Add-on module

Time synchronization kit with 0.1 ppm oscillator*. Supports IRIG-B, 1PPS, IEEE1588. For more information, including a full list of Precision Timing modules, visit the following page: Precision Timing Synchronization.

See here.

YES

YES

YES

YES

* Available PCIe slot required. Note that OP4510 and OP4512 simulators only have one PCIe slot.