Page Content
Table of Contents | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Have a question or need help?
Auibutton | ||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Solution
Cfm tabs page | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||||
The IEC 60870-5-104 slave I/O interface allows exchanging data over TCP with any industrial devices and SCADA systems. Using a standard network interface card, this protocol can be easily and rapidly integrated into any simulation model. With the proper user configuration, a driver is initialized on the target simulator at the start of the simulation and waits for one or more masters to connect to each slave to begin data transmission. The driver makes use of asynchronous threads in order to service each slave. This driver provides an asynchronous TCP/IP communication interface and an IP aliasing mechanism allowing to assign different IP addresses to each slave/outstation instance even if a single physical network interface (i.e., Ethernet port) is used. |
Cfm tabs page | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
| ||||||||||
IEC-60870-5-104 is an International Communications Protocol Standard for the telecontrol of electric power transmission systems. The standard specifies the use of permanent directly connected links between telecontrol stations. |
Software Platform Compatibility
Auibutton | ||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Auibutton | ||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Product Selection Guide
IEC 60870-5-104 Slave requires software license OP3241, which comes with 50 data points. Visit this page more information on data points.
If additional data points are required, then they may be added via product OP3050.
Since real-time simulators come with one available Ethernet port, if additional physical Ethernet ports are required on the real-time simulator, these can be added via kit.
Note that for applications requiring many Ethernet ports,the OP4510 and OP4512 simulators are not recommended.
Type | Description | Product Number | Simulator Compatibility | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
OP4510v2 | OP5033XG | OP5600v2 | OP5700 | |||||||||
Driver | Driver license for IEC 60870-5-104 Slave protocol for exchange of data of telecontrol communication system. 50 data points are included. For additional data points, add product OP3050 (see below). | OP3241 | YES | YES | YES | YES | ||||||
Additional data points | License for additional I/O data points for Ethernet-based communication protocols. 1,000, 5,000, or 30,000 (unlimited) data points may be added. License OP3241 is required. | OP3050-1000 | YES | YES | YES | YES | ||||||
Add-on module | Dual-port PCIe X1 Gigabit Ethernet Kit for OP4xxx Series of Real-Time Simulators*. Can be added if more physical Ethernet ports are required for Modbus TCP. | OP3821 | OP4510v2 | |||||||||
OP3821-4610 | OP4610XG | |||||||||||
Add-on module | Intel I350T4V2 Quad Port Ethernet Server Adapter 10/100/1000 Mbps for OP5xxx Series of Real-Time Simulators*. Can be added if more physical Ethernet ports are required for Modbus TCP. | I350T4V2BLK | YES | YES | YES |
* Available PCIe slot required. Note that OP4510 and OP4512 simulators only have one PCIe slot.