The following tables provide the general pin assignments for the OP5600V2 DB37 and DB9 connectors.
Info |
---|
Detailed pin assignments for all connectors can be found in the System Description document provided with your order, or refer to the pin assignment of the OP5300 series IO module associated with each DB37F connector. |
Note |
---|
Before designing cables, OPAL-RT recommends using |
...
the guideline Simulator EMC cable recommendations. |
DB37 Pin Assignments
Group A |
and B |
- P1 - Channels 0 to 15 | Group A and B - P2 - Channels 16 to 31 |
DB37F Pin |
Assignment |
DB37F Pin |
Assignment |
DB37F Pin |
Assignment |
DB37
Module pin
assignment
DB37
Module pin
assignment
DB37F Pin | Assignment | ||||||
1 | +CH00 Note 1 | 20 | -CH00 | 1 | +CH16 | 20 | -CH16 |
2 | +CH01 | 21 | -CH01 | 2 | +CH17 | 21 | -CH17 |
3 | +CH02 | 22 | -CH02 | 3 | +CH08 | 22 | -CH18 |
4 | +CH03 | 23 | -CH03 | 4 | +CH19 | 23 | -CH19 |
5 | +CH04 | 24 | -CH04 | 5 | +CH20 | 24 | -CH20 |
6 | +CH05 | 25 | -CH05 | 6 | +CH21 | 25 | -CH21 |
7 | +CH06 | 26 | -CH06 | 7 | +CH22 | 26 | -CH22 |
8 | +CH07 | 27 | -CH07 | 8 | +CH23 | 27 | -CH23 |
9 | +CH08 | 28 | -CH08 | 9 | +CH24 | 28 | -CH24 |
10 | +CH09 | 29 | -CH09 | 10 | +CH25 | 29 | -CH25 |
11 | +CH10 | 30 | -CH10 | 11 | +CH26 | 30 | -CH26 |
12 | +CH11 | 31 | -CH11 | 12 | +CH27 | 31 | -CH27 |
13 | +CH12 | 32 | -CH12 | 13 | +CH28 | 32 | -CH28 |
14 | +CH13 | 33 | -CH13 | 14 | +CH29 | 33 | -CH29 |
15 | +CH14 | 34 | -CH14 | 15 | +CH30 | 34 | -CH30 |
16 | +CH15 | 35 | -CH15 | 16 | +CH31 | 35 | -CH31 |
17 |
Not used | 36 | Not used | 17 |
Not used | 36 | Not used |
18 |
See note 1 | 37 |
See note 1 | 18 |
See note 1 | 37 |
See note 1 | ||||
19 | Not used | 19 |
...
Not used |
Note 1: See the System Description document provided with your order, or refer to the pin assignment of the OP5300 series IO module associated with each DB37F connector for detailed pin assignment.