Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

This feature outputs a synchronization signal on the TRIG OUT  BNC  BNC that is available on the front panel of  of the Base Module. It is used to synchronize a capture device such as an oscilloscope or a logic analyzer.

...

Three controls are made available to the user in the Base Module run-time panel:

  • Trig. mode: allow the user to specify which signal to output at the BNC connector. Supported values are:

Value

Description

0

Output a pulse at a specific engine position specified by Trig. Output value.

1

Output the model synchronization signal

2

(

*

)

Output the high-resolution signal (Hi RES) produces by the RPG module

3

(

*

)

Output the RESET signal of the RPG module

...

*

...

Modes 2 and 3 are not yet supported

  • Trig. output: specify the angular position (expressed as a high-resolution count, .i.e. 5000 for 500° at 0.1 resolution) at which the trigger output produces the pulse. Compatible only with trigger mode = 0.
    Trig. enable:

     activate

     activate the trigger output (1), or disable it (0).