This feature outputs a synchronization signal on the TRIG OUT BNC BNC that is available on the front panel of of the Base Module. It is used to synchronize a capture device such as an oscilloscope or a logic analyzer.
...
Three controls are made available to the user in the Base Module run-time panel:
Trig. mode: allow the user to specify which signal to output at the BNC connector. Supported values are:
Value | Description |
---|---|
0 | Output a pulse at a specific engine position specified by Trig. Output value. |
1 | Output the model synchronization signal |
2 |
* |
Output the high-resolution signal (Hi RES) produces by the RPG module | |
3 |
* |
Output the RESET signal of the RPG module |
...
*
...
Modes 2 and 3 are not yet supported
Trig. output: specify the angular position (expressed as a high-resolution count, .i.e. 5000 for 500° at 0.1 resolution) at which the trigger output produces the pulse. Compatible only with trigger mode = 0.
activate
Trig. enable:activate the trigger output (1), or disable it (0).