Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Table of Contents
maxLevel1
indent20px
stylecircle

...

Image Modified

Description

This model is a general-purpose rotating excitation system model that, given the proper parameters and tuning, can represent a variety of exciters. The REXSYS component was developed in line with the reference [1].

Mask and Parameters

AVR parameters

Expanding the "REXSYS AVR diagram" displays the block diagram in the parameters window.



Name

Description

Unit

Parameter range

Tr

Regulator input filter time constant

s

-

Kvp

Voltage regulator proportional gain

-

Kvp ≠ 0

Kvi

Voltage regulator integral gain

-

-

VImax

Voltage regulator input limit

pu

-

Ta

Voltage regulator time constant

s

 

Tc1

First stage lead-lag numerator time constant

s

-

Tb1

First stage lead-lag denominator time constant

s

-

Tc2

Second stage lead-lag numerator time constant

s

-

Tb2

Second lead-lag denominator time constant

s

-

VRmax

Maximum voltage regulator output

pu

-

VRmin

Minimum voltage regulator output

pu

-

Kf

Rate feedback gain

-

-

Tf

Rate feedback time constant

s

If Tf < 0.2, then Tf = 0.2

Tf1

Feedback lead-lag numerator time constant

s

-

Tf2

Feedback lead-lag denominator time constant

s

-

Fbf

Rate feedback signal selector

-

[1, 2, 3]

...

FCR and Exciter Parameters

Expanding the "FCR and Exciter diagram" displays the block diagram in the parameters window.

Name

Description

Unit

Variable = {Possible Values}

Kip

Field current regulator proportional gain

-

-

Kii

Field current regulator integral gain

-

-

Tp

Field current bridge time constant

s

-

VFmax

Maximum exciter field current

pu

-

VFmin

Minimum exciter field current

pu

-

Kh

Field voltage controller feedback gain

-

-

Ke

Exciter constant related to self-excited field

-

-

Te

Exciter time constant

s

 

Kc

Rectifier loading factor proportional to commutating reactance

-

-

Kd

Exciter demagnetizing factor

-

-

Se2, Se1

Exciter saturation factor at the corresponding Vex

pu

-

Ve2,Ve1

Exciter voltage for the exciter saturation function

pu

Ve1 > Ve2 > 0

F1imf

Power supply limit factor

-

-

...

The HYPERSIM simulation option Set Initial Conditions must be checked for the calculation to work properly.

References

1. PSS®E 34.2.0 Model Library. NY, USA: Siemens Industry, Inc., 2017.