Description

The photovoltaic generation system (PVGS) is shown in the figure below. The PVGS features a PV array that is connected to an inverter via a boost DC-DC converter. The PV array model contains many types of modules predefined from the database of the California Energy Commission (CEC)

Cfm footnote
textPhotovoltaic (PV) Modules: Energy Commission’s Solar Equipment Lists, California Energy Commission, Nov. 2018. Available Online: https://www.gosolarcalifornia.ca.gov/equipment/pv_modules.php
id4bjkt9us436
. More than 21,000 modules from leading manufacturers are listed in this database which includes the manufacturer's specifications measured for standard test conditions (STC). meaning Irradiance of 1000 W/m2 and 25° C.

...

The PV_Array panel is shown below. This panel contains all the parameters to tune the technology and desired output power from the PV. The panel was implemented from a MATLAB/Simulink example model available online

Cfm footnote
text"250-kW Grid-Connected PV Array" Institut de recherche d'Hydro-Québec (IREQ)  (available: https://www.mathworks.com/help/physmod/sps/examples/250-kw-grid-connected-pv-array.html)
id3se6z33haao
.

PV Array Parameters

...

Name

Description

Unit

Nser

Number of PV modules connected in series.

-

Npar

Number of PV modules connected in parallel.

-

Ncell

Number of cells per module.

-

Vmp

Voltage at maximum power point for one module at nominal irradiance (1000 W/m2 ) and temperature (25 °C).

V

Imp

Current at maximum power point for one module at nominal irradiance (1000 W/m2 ) and temperature (25 °C).

A

Pmax

Maximum power 

W

Voc

Open circuit voltage for one module.

V

Isc

Short circuit current for one module.

A

Beta

Temperature coefficient at Voc

%/°C

Alpha

Temperature coefficient at Isc

%/°C

IL

Light generated current

A

I0

Diode saturation current

A

Diode ideality factor

Ideality factor of the diode.

-

Rsh

Shunt resistance

Rs

Series resistance

PV array Database Parameters

Below figure shows the Database tab of PV model. This tab lets you choose a PV from the database of the California Energy Commission (CEC). Once the selected module, the user must click Load parameters to load the model with the respective parameter values.

...

Boost Converter Parameters

The boost converter control parameters contain the RLC parameters together with the duty-cycle control, this duty-cycle depends on the active power regulator.

...