Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Description

Essentially, both of these models are identical, the TCR branch being a specific case of the TSC branch. Resistances R and r respectively represent ohmic losses in the capacitor and the reactor. One of these elements can be ignored by assigning a zero value to it in the control panel. The two resistances, the capacitor and the reactor form a type of black box. Hence, it is not possible to measure the voltage across one of the resistances or the reactor. However, the voltage across the capacitor is calculated and available as a signal. This is also the case for the voltages across the thyristors.



Panel
borderColor#627781
titleColor#627781
borderWidth1
borderStylesolid
titleTable of Contents

Table of Contents
indent20px
stylecircle
printablefalse


Mask and Parameters


Parameters

NameDescriptionUnitVariable = {Possible Values}
Control TypeControl inputs to the block - External input pins or sensors

Precision Valve

Enable: Precision valve is used which corrects for any errors due to digitization

Disable: Precision feature not used


{Enable, Disable}
ConnectionsY ground; Y floating; Delta

r Resistance in parallel with branch reactorOhm{(0,1e12]}
LSeries inductanceH{(0,1e12]}
RBranch resistanceOhm{(0,1e12]}
CBranch capacitanceF{(0,1e12]}
RsnubberSnubber resistanceOhm{[0,1e12]}
CsnubberSnubber capacitanceF{[0,1e12]}
RopenValve resistance when openOhm{(0,1e12]}
RcloseValve resistance when closedOhm{(0,1e12]}
IminChopping currentA{[0,1e12]}
FbovForward break overvoltageV{[0,1e12]}
RbovReverse break overvoltageV{[0,1e12]}
TqTime for the valve to stop conductings{[0,1e12]}
VminMinimum forward voltage across valve to conductV{[0,1e12]}


Ports, Inputs, Outputs and Signals Available for Monitoring

Ports


NameDescription
Net_1Network connection (supports only 3-phase connections)


Inputs


NameDescription

D

Delay used for the precision valve measured from changing point to current time step

P

Binary coded firing pulses


Outputs

None

Sensors


Name

Description

Unit

CMD12_x where (x= a,b,c)

Firing pulse of the positive valve in the x branch


CMD21_x where (y= a,b,c)

Firing pulse of the negative valve in the x branch


I_x where (x= a,b,c)

Current through the branch

A

STATE12_x(where x=a,b,c)

State of the positive valve in the x branch


STATE21_x(where x=a,b,c)

State of the negative valve in the x branch


D

Delay used for the precision valve measured from changing point to current time step

s

P

Binary coded firing pulses


DelayImpInt

Firing delay (as a fraction of calculation step) calculated by the internal command

s

DelayImpExt

Firing delay (as a fraction of calculation step) calculated by an external command

s

DelayImp

Firing delay (as a fraction of calculation step)

s

DelayImpUsed

Firing delay (as a fraction of calculation step)

s