Mask and Parameters
General
| Name | Description | Unit | Variable = {Possible Values} |
|---|---|---|---|
| Vmin | Forward voltage drop | V | {[0,1e12]} |
| Ropen | Open state resistance | Ohm | {[0,1e12]} |
| Rclose | Closed state resistance | Ohm | {(0,1e12]} |
| Rsnubber | Snubber resistance | Ohm | {(0,1e12]} |
| Csnubber | Snubber capacitance | F | {[0,1e12]} |
| Control type | External Input pins: Schematic control signal; the received integer is converted to a binary string where each digit corresponds to a phase External Input sensors: Target digital inputs |
Advanced
| Name | Description | Unit | Variable = {Possible Values} | |
|---|---|---|---|---|
| Fail reset | Fail reset | {Enable, Disable} | ||
| Precision valve | Enable: Enables recalculation of the state switch command using exact time between steps (as percentage of time step) Disable: does not use precision valve | {Enable, Disable} | ||
| Imin | Holding current | A | {[0,1e12]} | |
| Tq | Thyristor turn off time | s | {[0,1e12]} | |
| Fbov | Forward break over voltage | V | {[0,1e12]} | |
| Rbov | Reverse break over voltage | V | {[0,1e12]} | |
Ports, Inputs, Outputs and Signals Available for Monitoring
Ports
| Name | Description |
|---|---|
| Net_1 | Network connection |
| Net_2 | Network connection |
Inputs
| Name | Description |
|---|---|
| D | Delay used for precision valves |
| P | Binary coded firing pulses |
Outputs
None
Sensors
| Name | Description | Unit |
|---|---|---|
| FailSig | Fail reset signal | |
| I | Diode current | A |
| Isw | Switch current | A |
| Delay | Delay due to forward voltage drop | s |
| DelayExt12 | Delay for external trigger | s |
| Cmd12 | Signal state command | |
| CmdExt12 | Signal state external command | |
| State12 | Diode state |