Mask and Parameters
Name | Description | Unit | Variable = {Possible Values} | |
---|---|---|---|---|
Precision Valve model | Enable: Recalculation of the switch operation using the exact time between steps (in percentage of Ts) of the valve command Disable: precision valve model not used | |||
Rsnubber | Snubber resistance | Ohm | {0,1e12} | |
Csnubber | Snubber capacitance | F | {0,1e12} | |
Imin | Holding current | A | {0,1e12} | |
Ropen | Switch open resistance | Ohm | {0,1e12} | |
Rclose | Switch close resistance | Ohm | {0,1e12} | |
Control Type | External (input pins) or External (input sensors from hardwarae) |
Ports, Inputs, Outputs and Signals Available for Monitoring
Ports
Name | Description |
---|---|
Net_1 | Network connection; the "+" indicates the current measurement direction (supports only 3-phase connections) |
Net_2 | Network connection (supports only 3-phase connections) |
Inputs
Name | Description |
---|---|
D | Delay used for precision valve. It is expressed as a fraction of time step |
P | Binary coded firing pulses. Bits 0,1,2: forward pulses of Phases A,B,C. For single phase only Phase A is used |
Outputs
None
Sensors
Name | Description | Unit |
---|---|---|
D | Delay used for precision valve. | |
P | Binary coded firing pulses | |
DelayExt12 | Time delay through external signal | s |
CmdExt12 | Command signal through external signal | |
State12 | Switch status | |
Cmd12 | Switch command | |
I | Switch current | A |
Delay | Switch delay | s |