Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Quick Nav

Table of ContentsmaxLevel2minLevel2

Page Content

Table of Contents
minLevel1
maxLevel6
include
outlinefalse
indent
excludePage Content|Have a question or need help?
typelist
class
printablefalse

Have a question or need help? 

custom
Auibutton
custom-iconemail
icon
true
externalUrlhttps://www.opal-rt.com/contact-sales-team/
color#F4F5F6
filterSpacefalse
iconfa-user
destinationexternalUrl
textColorPaletteDefault
typeprimary
titleGet in touch
typetextColorprimary#091E42
url
targettrue
selectedUrlhttps://www.opal-rt.com/contact-sales-team/
targetan.spaceKeyCPM
idjhp17cghey
backgroundColorPaletteDefault

Solution

Cfm tabs page
colorPalettesDefault
tabsPageTitleSummary
primaryTabtrue
color#0052CC
idyn26w34itfo
backgroundColorPaletteDefault

The PROFINET IO-Device driver allows the simulator to communicate with one or multiple pieces of equipment configured with a PROFINET IO - Controller interface.
The simulator can instantiate to which controllers can connect and send read/write commands.

The PROFINET IO-Device interface can operate over TCP/IP using an Ethernet physical link connected to a network and be detected via DCP (Discovery and Configuration Protocol).
The user must load a GSDML file and select the correct configuration that matches the network configuration of the card and IO controller(s).

Cfm tabs page
colorPalettesDefault
tabsPageTitleAbout PROFINET
color#0052CC
id4bop1xg5gtt
backgroundColorPaletteDefault

PROFINET (Process Field Network) is an industry technical standard for data communication over Industrial Ethernet, designed for collecting data from, and controlling equipment in industrial systems, with a particular strength in delivering data under tight time constraints. The standard is maintained and supported by Profibus PROFIBUS and Profinet PROFINET International, an umbrella organization headquartered in Karlsruhe, Germany (source: Wikipedia).

Image RemovedImage Added
Image RemovedImage Added

Software Platform Compatibility

Image Removed

PROFINET IO-Device Documentation

Auibuttoncustom-icondocument

Image Added

Auibutton
externalUrlhttps://opal-rt.atlassian.net/wiki/spaces/PRD/pages/143461570/PROFINET
color#F4F5F6
filterSpacefalse
icon

custom

atlaskit-DocumentIcon
destinationexternalUrl
textColorPaletteDefault

id

type

wxwno7ramt

primary
titlePROFINET documentation for RT-LAB

typeprimary

textColor#091E42

backgroundColorPalette

target

Default

true

url

selectedUrlhttps://opal-rt.atlassian.net/wiki/spaces/PRD/pages/143461570/PROFINET

target

an.spaceKey

true

CPM

Supported features

The following is a list of the features supported by the driver:

  • DCP

  • GSDML parser for configuration

  • Multiple cards support

  • Channel diagnosis

  • IO status (IOCS/IOPS)

  • Communication watchdog

  • Shared device access

  • MRP (Media Redundancy Protocol)

Limitations

The following is a list of the limitations of the driver:

  • No alarm handling

  • No fast start-up

  • No multicast device-to-device communication

  • No support for iPar (parameter server)

  • No support for time synchronization

  • No support for ProfiDrive or ProfiSafe profiles

idwosyxzm4wrp
backgroundColorPaletteDefault


Product Selection Guide

Type

Description

Product Number

(s)Description

Simulator Compatibility

Additional requirement(s)

OP4510-series

OP5600-series

OP5700-series

OP4610XG

Software

OP3145

Driver - PROFINET-IO Device license
(one license per CIFX 50E-RE PCIe board)

A Hilscher CIFX 50E

OP4510v2
OP4512
OP4610XG

OP5033XG

OP5600v2
OP5650

OP5700
OP5705XG
OP5707XG

Driver

Driver license for PROFINET IO protocol.One license per CIFX 50E-RE PCIe board is required. A Hilscher CIFX 50E-RE PCIe board (Product

Number OP3113-OP4510, OP3113-OP5030 or, OP3113-OP56xx-OP57xx

Number OP3113, see below) is required for each slave driver.

OP3145

Image Removed

YES

YES

Image Removed

YES

Image Removed

YES

Requires OP3113-OP4510, OP3113-OP5030 or, OP3113-OP56xx-OP57xx installed on Real-Time Simulator.

External hardware

Add-on module

EtherCAT CIFX 50E-RE PCIe Communication Interface*.
One driver license per CIFX 50E-RE PCIe board is required (sold separately)

OP3113-OP4510

OP4510v2
OP4512

OP3113-OP5030

YES

OP3113-OP56xx-OP57xx

CIFX 50E-RE Communication Interface PCIe for OP45xx, OP56xx or OP57xx series simulators

Image RemovedImage RemovedImage RemovedRequires available PCIe slot. Note: OP4510 supports a maximum of one (1) PCIe device

YES

YES