Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

This product meets the essential requirements of applicable European Directives as follows:

...

Certifying Body

...

Standard Number

...

Standard Name

...

Specifications

...

Minimum performance requirement criteria

...

FCC part 15 (2022), subpart B

...

Conducted Emissions

...

Class A 150 kHz-30MHz

...

FCC part 15 (2018), subpart B

...

Radiated Emissions

...

Class A 30 MHz-21GHz

...

ICES-001 Issue 5 (2020)

...

Radiated Emissions

...

CSA CISPR 11:19 Group 1 - class A
30 MHz-1GHz

...

ICES-001 Issue 5 (2020)

...

Conducted Emissions

...

CSA CISPR 11:19 Group 1 - class A
150 kHz-30MHz

...

...

IEC61000-4-2 (2008)
 

...

Electrostatic Discharge Immunity

...

Contact: ±4 KV Air: ±8 KV

...

B

...

IEC61000-4-3 (2020)
 

...

Radiated Electromagnetic Field Immunity

...

80 MHz-1000MHz: 10 V/m
1.4 GHz-6 GHz: 3 V/m

...

A

...

IEC61000-4-4 (2012)

...

Electrical Fast Transient Immunity 

...

Power: ±2 KV, 5 kHz & 100 kHz
I/ O Ports: ±1 KV, 5 kHz & 100 kHz
Communication Ports: ±2 KV, 5 kHz & 100 kHz

...

B

...

IEC61000-4-5 (2014) A1 (2017)
 

...

Surge Immunity

...

Power: ±2 KV L-PE, ±1 KV L-L
I/O Ports: N/A
Communication Ports: N/A

...

B

...

IEC61000-4-6 (2013)

...

Immunity to Conducted Disturbances,
Induced by Radio-Frequency Fields

...

Power: 3 V
I/O Ports: 3 V
Communication Ports: 3 V

...

A

...

IEC61000-4-8 (2009)

...

Power Frequency Magnetic Field Immunity 

...

Continuous Field: 30A/m, 50 Hz & 60 Hz

...

A

...

IEC61000-4-11 (2020)

...

Voltage Dips, Short Interruptions and
Voltage Variation Immunity on AC Input

...

Voltage dips:
0%Un during 1 cycle
40%Un during 10 cycles (at 50 Hz)
40%Un during 12 cycles (at 60 Hz)
70%Un during 25 cycles (at 50 Hz)
70%Un during 30 cycles (at 60 Hz)

Short interruptions:
0%Un during 250 cycles (at 50 Hz)
0%Un during 300 cycles (at 60 Hz)

B
C
C
C
C

C
C

...

IEC61010-1:2010 (Third edition)

...

Single fault condition
Protective Conductor Abnormal
Cooling Abnormal
Input
Durability Of Markings
Applied Force
Permissible Limits For Accessible Parts
Impedance Of Protective Bonding Test
Dielectric Voltage Withstand
Humidity Conditioning
Capacitor Discharge
Stability 10 Deg
7.5.2 Handle Strength Test
7.6 Rack Mounting Test
Static Rigidity
Impact
Drop (Non-Hand Held Equipment)
Temperature

...

Include Page
OP4610XG Certification and Standards
OP4610XG Certification and Standards