This table summarizes the real-time simulation performance using OPAL-RT eHS solver for power systems and power electronics. 

Benchmark

Minimum Time-Step
(Minimum License Class)

Minimum Time-Step
(High Performance)

Minimum License Class Required

3-phase diode rectifier

250

230 ns

Not tested

100 ns

eHSx16

3-phase 2-level inverter

230 ns

100 ns

eHSx16

3-phase NPC converter

260 ns

110 ns

eHSx32

3-phase 2-level back-to-back converter

300 ns

95

100 ns

eHSx16

DAB converter

245 ns

95

100 ns

eHSx16

LLC converter

325

320 ns

95

100 ns

eHSx16

PMSM

215

220 ns

115

100 ns

eHSx16

Four PV power system

1280

2310 ns

230

280 ns

eHSx32

5-level inverter

660 ns

Not tested

eHSx64

600-node 20 kV distribution system

3 us

Not tested

4x eHS128