Documentation Home Page OPAL-RT Schematic Editor Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 4 Current »

This device allows current to flow in both directions but it is capable to block voltage only in forward direction (from the positive/collector to negative/emitter port). Its states depends on gate control signal (controlled commutation) and on the conditions imposed by the external circuit.

Parameters

image-20240124-193401.png

Internal on resistance (Ron)

The diode internal on resistance, in ohms (Ω).

Internal off Resistance (Roff)

The diode internal off resistance, in ohms (Ω).

Discrete-time switch conductance (Gs)

The signal to control on/off state of the switch.

See How to tune discrete-time switch condutance for detailed explanation.

Switch admittance (Gs)

The discrete-time switch conductance, in S.

Relaxation (Relax)

The relaxation parameter of the switch. Values can range between 0.1 for maximum performance or 10 for maximum stability.

See How to tune single switch parameters for detailed explanation.

Damping resistance (Rdamp)

Damping resistance value, in ohms (Ω).

See How to tune single switch parameters for detailed explanation.

Electrical Ports

  • From top to bottom, the electrical ports are the positive and negative ports of the source respectively named p1 and n1

Inputs

g

Digital input controlling the gate. This input could be assigned to a digital input channel or a signal coming from Simulink or HYPERSIM.

Characteristics

Advanced - Gen 4

Advanced parameters for Gen 4 solver architecture:

  • Discrete-time switch conductance (Gs)

are only visible when selecting Nodal Analysis (Gen4) circuit analysis method in Solver Settings.

Precision on how to tune this parameter can be found here: /wiki/spaces/FPET/pages/22924052.

Advanced - Gen 5

Advanced parameters for Gen 5 solver architecture:

  • Relaxation (Relax)

  • Damping resistance (Rdamp)

are only visible when selecting State-space Analysis (Gen5) circuit analysis method in Solver Settings.

Precision on how to tune those parameters can be found here: /wiki/spaces/FPET/pages/250380336.

  • No labels