Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

  • Xls: Armature leakage reactance (pu);
  • Xmd: Direct magnetizing reactance (pu);
  • Xmq: Quadrature magnetizing reactance (pu);
  • Xlkq1: Quadrature damper winding 1 leakage reactance (stator side) (pu);
  • Xlkq2: Quadrature damper winding 2 leakage reactance (stator side) (pu);
  • Xlfd: Field winding leakage reactance (stator side) (pu);
  • Xlkd: Direct damper winding leakage reactance (stator side) (pu);
  • Rs: Armature resistance (pu);
  • Rkq1: Quadrature damper winding 1 resistance (stator side) (pu);
  • Rkq2: Quadrature damper winding 2 resistance (stator side) (pu);
  • Rfd: Field winding resistance (stator side) (pu);
  • Rkd: Direct damper winding resistance (stator side) (pu);
  • Rg: Neutral connection resistance (pu);
  • H: Inertia constant (pu.s);
  • F: Friction constant (pu);
  • P: Number of poles;
  • N_slot: Number of stator slots;
  • N_cs: Number of conductors per slot;
  • N: Number of parallel windings per phase; Winding functions for complete phase and each individual windings.
  • No labels