Declaration of Conformity CE-UKCA

  File Modified

Manufacturer Name/Address:

OPAL-RT Technologies Inc.
1751 Richardson suite 1060
Montreal QC H3K 1G6 Canada
www.opal-rt.com 

This declaration of conformity is issued under the sole responsibility of: OPAL-RT Technologies Inc.

Product Model/Product

OP4512 with any of the following options

  • OP5330-3

  • OP5340

  • OP5342

  • OP5353

  • OP5360-3

  • OP5367-1

  • OP5367-3

  • OP5367-5

  • OP5369

  • OP5969-1

  • OP5969-2

  • OP5451 (PCIe Onestop kit)

Product Description

Simulator with Digital and Analog Input and Output cards intended for indoor use only.
Ratings: 100-240 VAC, 50-60 Hz, 8.0 A - 4.0 A, 400 W max, pollution degree 2

Product Category

Electrical equipment for measurement, control, and laboratory use.

CE Conformity with the Relevant Community Harmonization Legislation

  • 2014/30/EU - Electromagnetic Compatibility Directive

  • 2014/35/EU - Low Voltage Directive

  • 2011/65/EU & (EU) 2015/863  - Restriction of Hazardous Substances in Electrical and Electronic Equipment (RoHS) directive

  • 2012/19/EU - Waste from Electrical and Electronic Equipment (WEEE) Directive

UKCA Conformity with the Relevant Harmonization Legislation

  • Electromagnetic Compatibility Regulations 2016

  • Electrical Equipment (Safety) Regulations 2016

  • The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012

References to the standards in relation to which conformity is declared

Category

Standards

Test Specifications

Emissions:

EN61326-1 (2021) / EN61326-1 (2013)

EN55011 (2016) A1(2017)
CISPR11(2015) A1(2016) A2 (2019)

Conducted Emissions: Group 1 - class A 150 kHz-30 MHz
Radiated Emissions: Group 1 - class A 30 MHz-1 GHz

1GHz-18GHz

Immunity:

EN61000-4-2 (2009) / IEC61000-4-2 (2008)

Contact: ±4 kV Air: ±2 kV, ±4 kV, ±8 kV


IEC61000-4-3 (2006) A1 (2007) A2 (2010)

80 MHz-1000 MHz: 10 V/m
1.4 GHz-2 GHz: 3 V/m
2 GHz-2.7 GHz: 1 V/m


IEC61000-4-4 (2012)

Power: ±2 kV / 5 kHz
I/O Ports: N/A
Communication Ports (Ethernet): ±2kV / 5kHz


IEC61000-4-5 (2014)

Power: ±2kV L-PE / ±1kV L-L
I/O Ports: N/A
Communication Ports: N/A


IEC61000-4-6 (2013)

Power: 3 V
I/O Ports: N/A
Communication Ports (Ethernet): 3 V


EN61000-4-8 (2010)
IEC61000-4-8 (2009)

Continuous Field: 3 A/m


EN61000-4-11 (2004) A1(2017)
IEC61000-4-11 (2004) A1(2017)

Voltage dips:

  • 0%Un during half cycle

  • 0%Un during 1 cycle

  • 40%Un during 10 cycles (at 50Hz)

  • 40%Un during 12 cycles (at 60Hz)

  • 70%Un during 25 cycles (at 50Hz)

  • 70%Un during 30 cycles (at 60Hz)

Short interruptions:

  • 0%Un during 250 cycles (at 50Hz)

  • 0%Un during 250 cycles (at 60Hz)

Safety:

EN 61010-1
IEC 61010 Edition 3.1 2017-01

Test procedure: CB Scheme

  • No labels