The DC machine is modelled as a Norton equivalent which has a direct interface with the network component. The machine electrical parameters must be specified with real parameters (SI). The control of the machine can only be done externally through the mechanical speed or the mechanical torque.
The DC machine does not participate in the load flow
Mask and Parameters
The mask of the machine has two tabs:
- Electrical Parameters: General parameters of the machine
- Mechanical Data: Mechanical parameters of the machine
General Parameters tab
Name | Description | Unit | |
---|---|---|---|
Base power | Nominal power | kW | |
Base Voltage | Nominal Voltage | kV | |
Ra | Armature resistance | Ohm | |
Laa | Armature inductance | H | |
Rf | Field resistance | Ohm | |
Lff | Field inductance | H | |
Laf | Mutual inductance | H |
Mechanical Data tab
Name | Description | Unit | |
---|---|---|---|
Control type | Mechanical torque or speed control | - | |
Moment of inertia J | Moment of inertia | kgm2 | |
Friction Kd | Friction coefficient | Nm.s | |
Mechanical torque | User select if the mechanical torque characteristic is internal or external | - | |
Tmec | Torque points of the mechanical torque versus speed | Nm | |
Wmec | Speed points of the mechanical torque versus speed | rad/s |
Ports, Inputs, Outputs and Signals Available for Monitoring
Ports
Name | Description |
---|---|
A+ | DC machine positive connector of the armature. It supports single-phase connection. |
A- | DC machine negative connector of the armature. It supports single-phase connection. |
F+ | DC machine positive connector of the field. It supports single-phase connection. |
F- | DC machine negative connector of the field. It supports single-phase connection. |
Inputs
Name | Description | Unit |
---|---|---|
Torque or speed signal if the control is external | Nm or rad/s |
Outputs
None
Sensors
Name | Description | Unit |
---|---|---|
Ias | Armature current | A |
If | Field current | A |
Ps | Consumed power | W |
Tmec | Mechanical Torque | Nm |
Tmec_i | Load torque or speed | |
Wm | Mechanical speed | rad/s |
Wrpm | Mechanical speed | rpm |
Additional Information & Model Equations
The equations below describe the dc machine:
The mechanical torque and the dynamic equation are described as follows:
The figures below show the shunt and serial connections of the DC machine.
Shunt DC machine:
Series DC machine:
Limitations
This model does not take into account the saturation.
References
Analysis of Electric Machinery and Drive Systems, 2nd edition, Paul C. Krause, Oleg Wasynczuk, Scott D. Sudhoff.