Description
Opal-RT 1D-LookUp Table - This block is a 1D-lookup table with linear interpolation to model, in combination with the eHS, saturation characteristics of inductor, transformer or surger arrester (MOV). It is compatible with the eHS Gen4 and Gen5.
Mask
Inputs
LoadIn & LoadInSof (Load In & Load In Start of Frame): These inputs are used to configure the1D-lookuptable with its related breakpoints and values per table and synchronize the configuration coming from the CPU.
From eHS low latency outputs: This port is used to read real time states from the eHS block. It requires to be connected on the "Low latency outputs" port of the eHS block.
Outputs
FLWS Output:This output port provide a FLWS signal to feedback the 1D-lookuptable's states to the eHS block. It requires to be connected on one of the "Extra Ux" port of the eHS block.
Characteristics and limitations
Direct Feedthrough | NO |
Discrete sample time | YES |
XHP support | N/A |
Work offline | YES |
If you require more information, please contact https://www.opal-rt.com/contact-technical-support/.