ARTEMiS MMC 1P Cell
Documentation Home Page ◇ ARTEMiS Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
ARTEMiS MMC 1P Cell
Mask and Parameters
Snubber resistance | Snubber resistance value, only used in high impedance mode. |
---|---|
Snubber Capacitor | Snubber capacitor value, only used in high impedance mode. |
Cell capacitor | Value of the cell's capacitor. |
Resistance in shunt with the cell capacitor | Value of the discharge resistance for the cell's capacitor. |
Initial capacitor voltage | The initial voltage value of the cell capacitor. It can be a scalar if all the capacitors start at the same value. If a vector the same length then the total number of cell is used, the voltage for each cell’s capacitor can be set. |
Ron | The internal resistance of the selected device, in ohms. |
Number of cells | This determines how many cells are connected in series. A maximum of 50 cells can be connected in series. If more then 50 cells are required, a second MMC_1P block needs to be connected in series. |
Sample time | Time at which the capacitor voltage will be computed. |
Keep cell short-circuit upon error | Check this box if the cell capacitor should remain to 0 when an error occurs. |
Inputs and Outputs
Inputs
Upper gate (double) | double signals that controlled the upper switch gates. This signal has to be a vector of the same length as the number of cells. A signal value of 1 indicates the switch is conducting, while a value of zero indicates the switch is OFF. |
---|---|
Lower gate (double) | double signals that controlled the lower switch gates. This signal has to be a vector of the same length as the number of cells. A signal value of 1 indicates the switch is conducting, while a value of zero indicates the switch is OFF. |
Center (SPS) | Middle point of the cell. |
Common (SPS) | Common point of the cell. |
Outputs
Vc (double) | The voltage at the cell's capacitor, vector of same length then the number of cells. |
---|---|
Error (double) | Ouput 0 in normal operation and output 1 if a short-circuit occurs. When the “keep cell short-circuit upon error” is checked it will output the total number of short-circuited cells. |
Characteristics
Direct Feedthrough | No |
---|---|
Sample Time | Parameter |
Work Offline | Yes |
Dimensionalized | Yes |