Documentation Home Page Cell Monitoring Device Emulation Add-On for NI VeriStand Home page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Known Issues 1.0.1

  • CMDE-118: Disabling a device introduces a small delay in the SPI communication. As a result, it is not recommended to disable more than five consecutive devices. Consider alternating between enabled and disabled devices in the ring daisy chain if this is a concern.

  • CMDETT-29: The first cell over/under voltage read command sent to the ADBMS6830 or LTC6811 (RDSTATD and RDSTATB respectively) returns an incorrect value. Sending the command again returns the correct response.

 

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter