Known Issues 1.0.0
CMDETT-96: Sleep bit not getting properly activated for the ADBMS6830.
CMDETT-56: Timing issue present at all hardware configurations between the emulated devices and DIOs, leading to SPI communication problems in hybrid setups (Real devices and emulated devices in the same ring).
CMDETT-71: LTC6810, LTC6811 and LTC6813 use two’s compliments representation for voltage measurements for simulations, which differs from the actual behavior of the real devices.
CMDETT-47: SPI modes 1 and 2 for the ADBMS6815 and ADBMS6830 are inverted (to use mode 1, user should select mode 2, and to use mode 2 user should select mode 1).
CMDE-118: Disabling a device introduces a small delay in the SPI communication. As a result, it is not recommended to disable more than five consecutive devices. Consider alternating between enabled and disabled devices in the ring daisy chain if this is a concern.
CMDETT-26: When sending a register read command from SPI Master A to the LTC6811 or LTC6813, if the hex value of the first register after the command bits is greater than 0x7, a bit will be carried over to the command portion. This does not interfere with the registers' results.
CMDETT-29: The first cell over/under voltage read command sent to the ADBMS6830 or LTC6811 (RDSTATD and RDSTATB respectively) returns an incorrect value. Sending the command again returns the correct response.