Documentation Home Page HYPERSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Parameter set example

Two full parameter sets are shown in the following table as well as the original standard parameters. The conversion was done using Canay’s work.

Generic 4-pole turbo-alternator and 48-pole hydraulic generator models parameters:

ParametersTurbo-AlternatorHydraulic Generator
TypeRoundSalient
Sbase (MVA)675370
VbaseLL (kV)2413.8
wb (rad/sec)120π120π
Xls (pu)1.3372e-11.5723e-2
Xmd (pu)1.96339.6928e-1
Xmq (pu)1.83665.9328e-1
Xlkq1 (pu)2.0543e-14.5117e-1
Xlkq2 (pu)1.0138N/A
Xlfd (pu)3.0335e-14.8771e-1
Xlkd (pu)3.8567e-18.3011e-1
Rs (pu)1.8300e-32.6360e-3
Rkq1 (pu)2.4457e-21.9789e-1
Rkq2 (pu)3.0294e-2N/A
Rfd (pu)5.6863e-45.2903e-4
Rkd (pu)5.1693e-24.0598e-2
Rg (Ω)500500
H (pu.s)2.54.1
F (pu)00
Parameters448
N_slot60540
N_cs22
N26
Standard Parameters
Rs (pu)0.001830.002636
Xls (pu)0.2150.015
Xd (pu)2.0970.985
Xd' (pu)0.3950.340
Xd'' (pu)0.290.249
Xq (pu)1.970.609
Xq' (pu)0.6430.6
Xq'' (pu)0.290.272
Tdo' (s)10.6617.348
Tdo'' (s)0.0330.075
Tqo' (s)0.415N/A
Tqo'' (s)0.0560.14

Winding Function for Phase A (A1 and A2 Winding) of Generic Turbo-Alternator

Winding Function for Phase A (A1 and A2 Winding) of Generic Turbo-Alternator

Winding Function and its Spectral Analysis for Phase A (A1 to A6 winding) of Generic Hydraulic Generator

Winding Function and its Spectral Analysis for Phase A (A1 to A6 winding) of Generic Hydraulic Generator

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323