AC I Source
The current source always has a parallel impedance. This impedance is made up of series or parallel connected R, L, C elements.
Mask and Parameters
SI or pu units:
- SI: Specifies the values of the RLC elements, voltage, current or frequency in international units (ohm, henry, farad, volt, ampere and hertz);
- pu: Specifies the values of the RLC elements, voltage, current or frequency in pu;
Name | Description | Unit |
---|---|---|
Starting mode (Slow/Fast) | If “Fast”, the source is immediately activated or deactivated. If “Slow”, when the source is activated, the amplitude of the source increases linearly from zero to the steady-state value. When the source is deactivate, the amplitude of the source decreases linearly from the steady-state value to zero. | - |
RLC type | Series (series R, L, C) or parallel (parallel R, L, C) | - |
Base Power (total) | Base power for three phase | MVA |
Base voltage (rmsLN) | Base voltage phase to ground | kV |
Base Frequency | Base frequency | Hz |
Amplitude (peak) | Peak value of the amplitude for the source current in amperes (or pu) for each phase | A (or pu) |
Angle | Angle of phase A in degrees. The current source is always in balanced and positive sequence. | degrees |
R | Resistance value in ohms | ohms (or pu) |
L | Inductance value | henry (or pu) |
C | Capacitor value | farad (or pu) |
Ports, Inputs, Outputs and Signals Available for Monitoring
Ports
- The current source injects a current from one bus (port) to another (port), without grounding.
Inputs
- I input (current source): The current amplitude signal.
Outputs
- None
Sensors
- I(a, b, c)_label: Current signal (current source) (A).
OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323