GFM Signal Conditioning Three-Phase


image-20240607-163621.png

The Signal Conditioning block converts the voltage and current signals, measured at different measurement locations, into their respective per-unit values and transforms them into d-q coordinates. For d-q transformation, Cosine based Park transformation method has been used. This means, that at the beginning (t=0), the d-axis of the rotating frame is aligned with the phase A axis. In addition, the blocks do DC voltage measurement filtering and convert it into its per-unit value.

Mask and Parameters

The following information is required by the configuration mask of the Signal Conditioning block:

 

Parameter

Description

Units

Nominal Operating Voltage

The nominal line-to-line RMS voltage of the grid-forming converter 

V

Nominal Power

Nominal Capacity of the grid-forming converter 

VA

Nominal Frequency  

Nominal frequency of the grid-forming converter 

Hz

Nominal DC voltage

The nominal value of the inverter’s input DC voltage

V

DC Link Voltage Measurement Filter Cut-off Frequency

Cut-off frequency of the DC voltage measurement Low Pass Filter

rad/s

Inputs, Outputs, and Signals Available for Monitoring

Inputs

Parameter

Description

Units

Iinv

Current measured at the inverter side filtering inductor

A

Io

Output Current, measured at the output of the filter

A

Vo

Per Phase Output voltage, measured across the Filtering Capacitor

V

Vdc

Measured DC Voltage

V

wt

Angle variation with time, synchronized on zero crossings of the fundamental (positive sequence) of phase A

rad

Outputs

Parameter

Description

Units

Frequency_pu

Frequency of the Inverter Output Voltage

pu

Vo_RMS

RMS value of the output voltage

V

Vo_dq_pu

Direct and Quadrature axis voltage at the output

pu

Io_pu

Output Current, measured at the output of the filter

pu

Io_dq_pu

Direct and Quadrature axis current at the output

pu

Iinv_pu

Current measured at the inverter side filtering inductor

pu

Iinv_dq_pu

Direct and Quadrature axis current at the inverter side inductor of the filter

pu

Vdc_pu

Measured DC Voltage

pu