/
Multiphase Line

Documentation Home Page ePHASORSIM Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Multiphase Line

On this page:

In this section:

Introduction

The multiphase line can represent either a 1, 2, or 3-phase line. The impedance parameters of these lines can be presented as positive and zero sequence data or with full matrices. Note that to model the 1 or 2-phase line, only the full matrix presentation is acceptable. Thus, there are four types of multiphase line components in ePHASORSIM native library.

  • Single Phase Line

  • Two Phase Line

  • Three Phase Line with Full Data

  • Three Phase Line with Sequential Data

Single Phase Line

Parameters

Symbol

Description

Unit

Symbol

Description

Unit

ID

Line name

a unique name

Status

Connect/Disconnect status

Initial value 1 (0 for disconnected)

Length

Length of the line (non-zero)

Any unit

From1

First sending bus

a unique name

To1

First receiving bus

r11 (Ohm/length_unit)

see (*)

ohm/length_unit

x11 (Ohm/length_unit)

see (*)

b11 (uS/length_unit)

see (**)

uS/length_unit

Two Phase Line

Parameters

Symbol

Description

Unit

Symbol

Description

Unit

ID

Line name

a unique name

Status

Connect/Disconnect status

Initial value 1 (0 for disconnected)

Length

Length of the line (non-zero)

Any unit

From1

First sending bus

a unique name

From2

Second sending bus

To1

First receiving bus

To2

Second receiving bus

r11 (Ohm/length_unit)

see (*)

ohm/length_unit

x11 (Ohm/length_unit)

see (*)

r21 (Ohm/length_unit)

see (*)

x21 (Ohm/length_unit)

see (*)

r22 (Ohm/length_unit)

see (*)

x22 (Ohm/length_unit)

see (*)

b11 (uS/length_unit)

see (**)

uS/length_unit



b21 (uS/length_unit)

see (**)

b22 (uS/length_unit)

see (**)

Three Phase Line With Full Data

Parameters

Symbol

Description

Unit

Symbol

Description

Unit

ID

Line name

a unique name

Status

Connect/Disconnect status

Initial value 1 (0 for disconnected)

Length

Length of the line (non-zero)

Any unit

From1

First sending bus

a unique name

From2

Second sending bus

From3

Third sending bus

To1

First receiving bus

To2

Second receiving bus

To3

Third receiving bus

r11 (Ohm/length_unit)

see (*)

ohm/length_unit

x11 (Ohm/length_unit)

see (*)

r21 (Ohm/length_unit)

see (*)

x21 (Ohm/length_unit)

see (*)

r22 (Ohm/length_unit)

see (*)

x22 (Ohm/length_unit)

see (*)

r31 (Ohm/length_unit)

see (*)

x31 (Ohm/length_unit)

see (*)

r32 (Ohm/length_unit)

see (*)

x32 (Ohm/length_unit)

see (*)

r33 (Ohm/length_unit)

see (*)

x33 (Ohm/length_unit)

see (*)

b11 (uS/length_unit)

see (**)

uS/length_unit



b21 (uS/length_unit)

see (**)

b22 (uS/length_unit)

see (**)

b31 (uS/length_unit)

see (**)

b32 (uS/length_unit)

see (**)

b33 (uS/length_unit)

see (**)

Three Phase Line With Sequential Data

Parameters

Symbol

Description

Unit

Symbol

Description

Unit

ID

Line name

a unique name

Status

Connect/Disconnect status

Initial value 1 (0 for disconnected)

Length

Length of the line (non-zero)

Any unit

From1

First sending bus

a unique name

From2

Second sending bus

From3

Third sending bus

To1

First receiving bus

To2

Second receiving bus

To3

Third receiving bus

R0 (Ohm/length_unit)

Zero-sequence resistance, see (x)

ohm/length_unit

X0 (Ohm/length_unit)

Zero-sequence reactance, see (x)

R1 (Ohm/length_unit)

Positive-sequence resistance, see (x)

X1 (Ohm/length_unit)

Positive-sequence reactance, see (x)

B0 (uS/length_unit)

Zero-sequence capacitive charge, see (x)

uS/length_unit

B1 (uS/length_unit)

Positive-sequence capacitive charge, see (x)

uS/length_unit

(x) If the impedance format is chosen to be sequence data, then Z0 and Z1 must be non-zero.

(*) Configuration of Z matrix (R + j X)

(**) Configuration of B matrix

Available I/O Pins

No

Pin Description

Pin Type

Value/Unit

Instruction

No

Pin Description

Pin Type

Value/Unit

Instruction

1

Set/Get service status

I/O

1: In-service

0: Out-of-service

lineID/status

2

Get sending end current magnitude of wire j

O

A (RMS)

lineID/ImagFromj

where j is 1, 2 or 3

3

Get receiving end current magnitude of wire j

O

A (RMS)

lineID/ImagToj

where j is 1, 2 or 3

4

Get sending end current angle of wire j

O

Degree

lineID/IangFromj

where j is 1, 2 or 3

5

Get receiving end current angle of wire j

O

Degree

lineID/IangToj

where j is 1, 2 or 3

6

Get sending end active and reactive power of wire j

O

kW

kVAr

lineID/PFromj

lineID/QFromj

where j is 1, 2 or 3

7

Get receiving end active and reactive power of wire j

O

kW

kVAr

lineID/PToj

lineID/QToj

where j is 1, 2 or 3

8

Get active and reactive power loss of wire j

O

kW

kVAr

lineID/PLj

lineID/QLj

where j is 1, 2 or 3

Example

See the Line page in phasor08_IEEE13.xlsx file in ePHASORSIM example phasor08.

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter