OP4610XG2 Maintenance

Documentation Home Page ◇ Hardware Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

OP4610XG2 Maintenance

Page Contents

Inspecting and Cleaning Up the Dust Filters

There are two (2) dust filters located on the left side of the chassis, in front of the cooling fans.

The dust filters must never be clogged to ensure good airflow inside the unit and prevent overheating.
Effective cooling is necessary for the unit's optimal performance.
If the filter is dusty, it must be cleaned or replaced.

Overheating can damage the unit.
Avoid using the unit in dusty environments.

  • Visually inspect the dust filters at least every 6 months or more often if needed.

  • If the filters are dusty, clean them.

  • Replace the dust filters if they are damaged.
    Order part number 110-3129 (3U air filter).

Stop the unit and disconnect the power cord before cleaning or replacing the dust filters.

  • Remove the two (2) dust filters by removing the four (4) screws of each dust filter cover.

  • With a vacuum cleaner or compressed air:

    • Clean the dust filter

    • Clean the dust filter covers

    • Clean the dust filter fans

  • Reassemble the dust filter and their covers.

    image-20251105-183220.png

Cleaning Up the Power Supply Fan and Air Exhaust Vents

Using a vacuum cleaner or compressed air, clean:

  • The exhaust vents on the right side of the chassis

  • The power supply fan at the rear of the unit

image-20251105-190140.png
Exhaust vent cleaning (right side)
image-20260113-211109.png
Power supply cooling fan (rear)
  • Reinstall and reconnect the unit.

External Chassis Cleaning

Disconnect the power cord before cleaning.

  • Use a damp cloth to clean external surfaces.

  • Use mild detergent if needed.

    • Do not spray water or cleaning products on the unit.

    • Do not use harsh chemicals or solvents.

  • Use compressed air to remove dust if necessary.