Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

Saturable magnetizing inductance parameters file

Saturable inductor and saturable transformer share the same magnetizing inductance parameters

How to specify the magnetizing inductance parameters of a saturable inductor/transformer in the Schematic Editor?

The saturable inductor/transformer block uses a table-defined magnetizing inductance.

 

This file has to be in a specific format which is described below.

What is the format of the saturable magnetizing inductance parameters file ?

The saturable magnetizing inductance parameters are described in a JSON format. The following parameters must appear in the file.

Parameter (JSON key)

Value type

Unit

Description

Example

Parameter (JSON key)

Value type

Unit

Description

Example

magnetizingFluxBreakpoints

double[]

Wb

Core magnetizing flux

"magnetizingFluxBreakpoints": [
0.0,
0.0000129,
0.00002,
0.0000227,
0.0000236,
0.0000239
],

currentValues

double[]

A

Current through the magnetizing branch

"currentValues": [
0.0,
0.64,
1.28,
1.92,
2.56,
3.2
]

The examples provided above, when combined in a valid JSON format, would appear as follows:

{ "magnetizingFluxBreakpoints": [ 0.0, 0.0000129, 0.00002, 0.0000227, 0.0000236, 0.0000239 ], "currentValues": [ 0.0, 0.64, 1.28, 1.92, 2.56, 3.2 ] }

Parameter constraints

The following constraints applies the saturation characteristic:

where

is the magnetizing flux, and
is the magnetizing current.

Additionally, the number of elements of the array “magnetizingFluxBreakpoints“ shall be the same of “currentValues“.

OPAL-RT TECHNOLOGIES, Inc. | 1751, rue Richardson, bureau 1060 | Montréal, Québec Canada H3K 1G6 | opal-rt.com | +1 514-935-2323
Follow OPAL-RT: LinkedIn | Facebook | YouTube | X/Twitter