7.6 Setting Default Values for the SPWM Generators

Documentation Home Page Power Electronics Add-On for NI VeriStand Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.

7.6 Setting Default Values for the SPWM Generators

Next, we can configure the SPWM Generators used in the simulation.

  • In the Configuration Tree, expand Circuit Model >> SPWM Generators 

  • Configure the SPWM Generators by confirming that the Default Values of the relevant channels are configured as shown in the table below.

  • Click Save.

SPWM Carrier

 

Channel Name

Default Value

 

Modulation Index

1

 

Carrier Frequency

5000Hz

SPWM Frequency Generators

 

Channel Name

Default Value

 

SPWM Frequency Engine 0

60Hz

SPWM Generator 0

 

Channel Name

Default Value

 

Phase

 

Frequency Engine

0

SPWM Generator 1

 

 

Channel Name

Default Value

 

Phase

-120º

 

Frequency Engine

0

SPWM Generator 2

 

Channel Name

Default Value

 

Phase

120º

 

Frequency Engine

0

 

 

The default value of the Carrier Frequency channel is set to 5000Hz. The default values for the other channels listed above can be configured in a similar manner.

 