RTE Period Meter
Library
RT-EVENTS Signal Attributes
Block
Description
The RTE Period Meter block measures the period and frequency of its input signals. It can also measure the duty cycle and the duration of its high state (Ton) or low state (Toff).
The period and frequency output signals can be measured between consecutive rising edges or consecutive falling edges. The measurement between consecutive parameters allows the user to select one of these two modes.
The duty cycle, Ton and Toff outputs can be calculated during one calculation step or during one signal period interval. When the calculation step is selected, the times Ton and Toff are valued between 0 and the calculation step. The duty cycle is the ratio of the time Ton on the calculation step. When the signal period interval is selected, the Ton and Toff outputs are values between 0 and the signal period. The duty cycle is the ratio of the time Ton on the signal period. The measurement during one parameter allows the selection of these two modes. The following two figures present the difference between Signal Period and Calcultaiton Step modes.
The minimum frequency parameter is used when the inputs signal is at very low frequency. When the block has not detected edges since a time greater than the inactive period condition, the measured period and frequency are set respectively to infinity and zero.
When the frequency of the input is lower than the minimum frequency parameter, also note that the value of the duty cycle changes instantaneously between 0 and 1 depending of the logic level (Low or High) of the input signal. In some systems, this behavior can cause problems. The RTE Frequency Meter block has a different algorithm to treat the duty cycle when the frequency is lower than the minimum frequency.
Mask
Parameters
Display Period | Outputs the period of the input signal. |
---|---|
Display Frequency | Outputs the frequency of the input signal. |
Measurement between consecutive | Determines if the period and frequency outputs are measured between the consecutive rising or falling edges. |
Display Ton | Outputs the duration of the high state. |
Display Toff | Outputs the duration of the low state. |
Display Duty Cycle | Outputs the duty cycle. |
Measurement during one | Determines if the Ton, Toff and Duty Cycle are calculated relative to one calculation step or relative to one completed signal period. |
Minimum frequency | When the input signal frequency is lower than this value, the output frequency and period are 0 and Inf. |
Input
Input (RTE Boolean) | RTE Boolean signals to measure. |
---|
Output
Period (Double) | Signal periods in seconds. |
---|---|
Frequency (Double) | Signal frequencies in Hz. |
Ton (Double) | Duration of its high state in seconds. |
Toff (Doule) | Duration of its low state in seconds. |
Duty Cycle (Double) | The duty cycle in the range: [0..1]. |
Characteristics
Direct Feedthrough | Yes |
---|---|
Sample time | Inherited and fixed discrete. |
Work Offline | Yes |
Dimensionalized | Yes |
Examples
The rte_encoder.mdl model demonstrates how to use RT-EVENTS blocks to simulate an incremental encoder connected to a rotating object. This example also shows how to use blocks of the library to insert fault, to filter noise and to measure some characteristics of RTE Boolean signal. In this example, the RTE Period Meter block is used to measure the frequency of the incremental encoder.