Documentation Home Page ◇ RT-LAB Home Page
Pour la documentation en FRANÇAIS, utilisez l'outil de traduction de votre navigateur Chrome, Edge ou Safari. Voir un exemple.
RT-LAB | Release Notes 2025.4
Page Contents
- 1 Software Toolboxes Installed with
- 2 Improved
- 3 Fixed
- 4 Signal Visualization and Processing
- 4.1 Dashboards
- 5 I/O Interfaces
- 5.1 CAN
- 5.2 General maintenance
- 5.3 IEC61850
- 5.4 MODBUS slave
- 5.5 OPAL-RT Board
- 5.6 S-Function IOs
- 5.7 Synchronization
- 5.8 TCP-UDP
- 6 ARTEMiS - CPU-Based Electrical Toolbox
- 7 ePHASORSIM - CPU-Based Phasor-Domain Toolbox
- 8 FPGA-Based Power Electronics Toolbox
- 8.1 eHS Blockset
- 8.2 RT-XSG Blockset
Software Toolboxes Installed with
Toolbox | Version Number |
|---|---|
7.15 | |
2025.4 | |
3.4.5 | |
2.15 | |
4.8.0 |
Improved
Improved the license management to ensure the compatibility with OPAL-RTLinux versions 3.8 and higher.
Reduced the time required to open projects.
Added target information (name and ip) to the compilation log.
Fixed
Fixed an issue where GetControlSignalDescription API fails when .signal file contains more that 24K ControlSignals.
Fixed the issue where the model compilation could get stuck in the last steps.
Fixed CreatePackage API to allow conversion of subfolder paths to linux.
Fixed an issue with IEC61850 I/O interface that prevented configurations from updating properly in Dashboard.
Fixed the possibility to cancel a load when started.
Allowed the compilation of a project while another simulation launched by the same user is already running on the target.
Signal Visualization and Processing
Dashboards
I/O Interfaces
CAN
Fixed issue occurring when multiple receivers are configured with the same CAN ID
General maintenance
Removed I/O blocks that are no longer available on 64-bit operating system
ARINC429 MaxTechnologies
Applicom
NI-4461
Spectracom
Triphase
IEC61850
Fixed issue with GOOSE subscriber when a data point is mapped to a floating point and its data type is a double point status
MODBUS slave
Added option to simulate a failure of the TCP connection with the master
Added option to add a configurable delay before responding to read/write requests from the master
OPAL-RT Board
Added support for OP48H30 I/O card on Versal, including example models
Added support for OP4605XG2, OP4610XG2 and OP5707XG2 platforms
Improved model initialization time when using an I/O expansion box over MuSE
Fixed issue with loadin ports on 64-bit operating system
S-Function IOs
Improved model diagnostic for OP4810 and OP4815 I/O expansion boxes
Synchronization
Fixed issue with VLAN ID that was limited to 255 instead of 4095
TCP-UDP
Improved robustness of the reception when the transmitter send packet over multiple segments
ARTEMiS - CPU-Based Electrical Toolbox
Added support to RT-LAB 2025.4.
Added load-flow initialization option to the BESS block from MicroGridTestbedLibrary.
Improved compatibility of Artemis with ePHASORSIM.
Updated “GHOST Microgrid” example model.
Changed output of block Islanding Management from MicroGridTestbedLibrary, the PCC_V_data was separated into V_compare and V_val and the PCC_I_data was separated into I_compare and I_val.
Changed the example model “Microgrid_OP1420_Demo” to use the new “Islanding Management” and BESS blocks.
ePHASORSIM - CPU-Based Phasor-Domain Toolbox
Added Native Controllable Current Source
This component is currently only available through PowerFactory to ePHASORSIM import
This will supports the current source configuration of the Static Generator
Added support for Voltage Sources at PV busses
This will allow for multiple Voltage Sources in a transmission network
Added support for all the “Model” options of static generator for PowerFactory to ePHASORSIM import
Only
constvandconstqoptions are suported for thelocal controllerof static generator
Added
PoutandQoutpins that gives access to output power of the following componentsPositive Sequence Voltage Source
Controllable Current Source
Constant Impedance Load
Constant Current Load
Constant Power Load
Added load power report to the load flow results
This is available when the load flow results are exported
FPGA-Based Power Electronics Toolbox
eHS Blockset
New Features
Added support for Round rotor Synchronous Machine (RRSM) in Schematic Editor workflow
Added support for Salient pole Synchronous Machine (SPSM)
Added support XG2 platform in 3 official Versal bitstreams
Added AOMR v3 Gain/offset on the fly change to all official bitstreams.
Added FPGA Scope support for Machines to all OP481X official bitstreams.
Added LED support to all OP4610 official bitstreams.
Added better error handling for Schematic Editor components compatibility.
Added support of High density OP48H30 cards for OP481X chassis with 2 new official bitstreams.
Added migration guide from eHS Gen4 Nodal Analysis to eHS Gen5 State space analysis.
Added support of OP4300 chassis in eFPGASIM XSG Lib.
Added new API to pilot the eHS simulink block from command line.
Bug fixes
Fixed Reset Handling by AOMRv2 and AOMRv3
Fixed "Number of resolver pole pairs" parameter for the SCIM and DFIM machines
Fixed underestimated minimum time step of specific topologies in eHS Gen5
Fixed Pi Line section error handling
Fixed a voltage instability issue in the Dual Active Bridge example model.
Fixed serializer block for DataOut.
Fixed driver features configuration in multiple firmwares.
RT-XSG Blockset
Retrocompatible support for new XG2 motherboard for Versal Family
Fixed wrong ID for the expansion slot when empty
Fixed issue causing a overtemperature for the DIO of the OP48H30 when a hardware mismatch is present
Hidden reserved MGT blocks from the library browser