This product meets the essential requirements of applicable European Directives as follows:

The essential requirements of the directive 2014/30/EU are covered by the following harmonized standards:
EN61326-1 (2021) – Electrical equipment for measurement, control and laboratory use. The immunity test requirements used for this Product qualification are for the equipment intended to be used in an industrial electromagnetic environment.

This product is designed and manufactured in accordance with the directive 2014/35/EU. Presumption of conformity with the essential requirements of the directive is provided by compliance with the following harmonized standard: EN 61010-1:2010 + A1:2019
In addition, this product has been tested and certified under the IECEE CB Scheme and holds a CB Test Certificate demonstrating compliance with:

  • IEC 61010-1:2010

  • IEC 61010-1:2010 / AMD1:2016

Certifying Body

Standard Number

Standard Name

Specifications

Minimum Performance Requirement Criterion

Certifying Body

Standard Number

Standard Name

Specifications

Minimum Performance Requirement Criterion

FCC.png

FCC 47 CFR Part 15, Subpart B

Radiated Emissions

Class A, 30 MHz to 18 GHz

 

FCC 47 CFR Part 15, Subpart B

Conducted Emissions

Class A, 150 kHz-30MHz

 

ices.JPG

ICES-001 Issue 5, July 2020

Radiated Emissions

CISPR 11:2015+A1:2016+A2:2019 Group 1, Class A,
30 MHz to 1 GHz

 

ICES-001 Issue 5, July 2020

Conducted Emissions

CISPR 11:2015+A1:2016+A2:2019 Group 1, Class A,
150 kHz to 30 MHz

 

iec.JPG

 

CISPR 11:2015+A1:2016+A2:2019

Radiated Disturbance

Group 1 Class A (30 MHz to 1 GHz)

 

CISPR 11:2015+A1:2016+A2:2019

Mains terminal Disturbance voltage

Group 1 Class A , AC powered
(rated input power ≤ 20kVA)

 

IEC 61000-3-2: 2018

Harmonic Current Emissions

Harmonic Classification A

 

IEC 61000-3-3 :2013 + A1:2017

Voltage Fluctuations and Flicker

 

 

IEC 6100-4-3: 2006 + AMD1: 2017 + AMD2 :2020

Radiated Electromagnetic Field Immunity

80 MHz-1000MHz: 10 V/m
1.4 GHz-6 GHz: 3 V/m
80% AM (1kHz )

A

IEC61000-4-2: 2008

Electrostatic Discharge Immunity

Contact: ±4 kV Air: ±2kV, ±4kV, ±8 kV

B

EN 61000-4-5: 2006

Surge Immunity

AC Power: ±2 KV L-PE, ±1 KV L-L
I/O Ports: N/A, Communication Ports: N/A

B

IEC61000-4-4: 2012

Electrical Fast Transient/Burst Immunity

AC Power (including protective earth): ±2 kV, 5 kHz
I/O signal/control (including functional earth): ±1 kV, 5 kHz

B

IEC61000-4-6: 2013

Immunity to Conducted Disturbances,
Induced by Radio-Frequency Fields

AC Power (including protective earth):
0.15-80MHz, 3V RMS (unmodulated), 80% AM (1kHz)
I/O signal/control (including functional earth):
0.15-80MHz, 3V RMS  (unmodulated), 80% AM (1kHz)

A

IEC61000-4-11: 2020

Voltage Dips, Short Interruptions and
Voltage Variation Immunity on AC Input

Voltage dip: 0% during 1 cycle
Voltage dip: 40% during 10/12 cycles
Voltage dip: 70% during 25/30 cycles
Short Interruption: 0% during 250/300 cycles

B
C
C
C

IEC 61010-1:2010,
IEC 61010-1:2010/AMD1:2016

EN 61010-1:2010/A1
UL 61010-1 (3rd Ed.)
CAN/CSA C22.2 No. 61010-1-12
JIS C 1010-1 (2019)

Including applicable national differences.

Testing in single fault conditions
Mains supply
Durability of markings
Determination of accessible parts
Levels in normal condition
Levels in single fault condition
Cross-sectional area of bonding conductors
Bonding impedance of permanently connected equipment
Insulation requirements
Enclosure rigidity test
Constructional requirements
Temperature Measurements
Insulating material
Cleaning
Sound level
Batteries and battery charging

4.4
5.1.3 c)
5.3
6.2
6.3.1
6.3.2
6.5.2.2
6.5.2.5

6.7
8.2
9.3.2
10
10.5.3
11.2
12.5.1
13.2.2