OP1400PR PHIL Prime - OP8110 4Q Power Amplifier Certification and Standards
This product meets the essential requirements of applicable European Directives as follows:
The essential requirements of the directive 2014/30/EU are covered by the following harmonized standards:
EN61326-1 (2021) – Electrical equipment for measurement, control and laboratory use. The immunity test requirements used for this Product qualification are for the equipment intended to be used in an industrial electromagnetic environment.
This product is designed and manufactured in accordance with the directive 2014/35/EU. Presumption of conformity with the essential requirements of the directive is provided by compliance with the following harmonized standard: EN 61010-1:2010 + A1:2019
In addition, this product has been tested and certified under the IECEE CB Scheme and holds a CB Test Certificate demonstrating compliance with:
IEC 61010-1:2010
IEC 61010-1:2010 / AMD1:2016
Certifying Body | Standard Number | Standard Name | Specifications | Minimum Performance Requirement Criterion |
|---|---|---|---|---|
FCC 47 CFR Part 15, Subpart B | Radiated Emissions | Class A, 30 MHz to 18 GHz |
| |
FCC 47 CFR Part 15, Subpart B | Conducted Emissions | Class A, 150 kHz-30MHz |
| |
ICES-001 Issue 5, July 2020 | Radiated Emissions | CISPR 11:2015+A1:2016+A2:2019 Group 1, Class A, |
| |
ICES-001 Issue 5, July 2020 | Conducted Emissions | CISPR 11:2015+A1:2016+A2:2019 Group 1, Class A, |
| |
| CISPR 11:2015+A1:2016+A2:2019 | Radiated Disturbance | Group 1 Class A (30 MHz to 1 GHz) |
|
CISPR 11:2015+A1:2016+A2:2019 | Mains terminal Disturbance voltage | Group 1 Class A , AC powered |
| |
IEC 61000-3-2: 2018 | Harmonic Current Emissions | Harmonic Classification A |
| |
IEC 61000-3-3 :2013 + A1:2017 | Voltage Fluctuations and Flicker |
|
| |
IEC 6100-4-3: 2006 + AMD1: 2017 + AMD2 :2020 | Radiated Electromagnetic Field Immunity | 80 MHz-1000MHz: 10 V/m | A | |
IEC61000-4-2: 2008 | Electrostatic Discharge Immunity | Contact: ±4 kV Air: ±2kV, ±4kV, ±8 kV | B | |
EN 61000-4-5: 2006 | Surge Immunity | AC Power: ±2 KV L-PE, ±1 KV L-L | B | |
IEC61000-4-4: 2012 | Electrical Fast Transient/Burst Immunity | AC Power (including protective earth): ±2 kV, 5 kHz | B | |
IEC61000-4-6: 2013 | Immunity to Conducted Disturbances, | AC Power (including protective earth): | A | |
IEC61000-4-11: 2020 | Voltage Dips, Short Interruptions and | Voltage dip: 0% during 1 cycle | B | |
IEC 61010-1:2010, Including applicable national differences. | Testing in single fault conditions | 4.4 6.7 |
|