ML605EX1 Resolver Out
Block
Mask
Description
The ML605EX1 Resolver Out is based on the basic resolver which is a two-pole resolver. The Resolver Out block is used to control the resolver.
This block has the following properties and features:
- Possibility to use 2 resolvers per block.
- Real-time adjustments of the speed, amplitude (carrier, sin and cos), frequency (carrier), and offset (sin and cos).
- Carrier select between an internal carrier and an external carrier.
Parameters
Controller Name | Bind this block to an OpCtrl ML605EX1 block by entering the same 'Controller Name' as specified in the OpCtrl ML605EX1 block. The OpCtrl ML605EX1 block controls the initialization of the settings of one specific ML605 card in the system. |
---|---|
DataIn port number | Enter the index of the DataIn port to be controlled by this block, in the range [1:32]. |
Slot info | This non-editable parameter displays the physical location of the analog output channels related to the selected DataIn port, as obtained from the parsing of the configuration file. |
Number of resolver signals | The block can use between 1 and 2 resolvers. To use 2 resolvers, it is required to set the number of resolvers in the block parameters and to use a 2:1 multiplexer before sending the data into each respective data input. |
Carrier Select Mode | The user can select to use an internal carrier or an external carrier.
|
Inputs
Speed | Set the speed of the simulated rotor. The value is represented in Hz. Range of values: -20000 to 20000. |
---|---|
Car.Amp | Carrier amplitude if no external exciter is used. The value is represented in Volts. Range of values: 0 to 15. |
Car.Freq | Carrier frequency if no external exciter is used. The value is represented in Hz. Range of values: 0 to 95000. |
Sin.Amp | Sine of the modulated amplitude. The value is represented in Volts. Range of values: 0 to 15. Due to hardware limitations, the product of Car.Amp and Sin.Amp should be less than 15. |
Sin.Bias | Sine offset. The value is represented in Volts. Range of values: -15 to 15. |
Cos.Amp | Cosine of the modulated amplitude. The value is represented in Volts. Range of values: 0 to 15. Due to hardware limitations, the product of Car.Amp and Sin.Amp should be less than 15. |
Cos.Bias | Cosine offset. The value is represented in Volts. Range of values: -15 to 15. |
Outputs
The Status output returns the following values:
Value | Description |
---|---|
0 | No error. |
-1 | Block could not be matched with an OpCtrl ML605EX1 block (check the 'Controller Name' value), or ML605 card initialization problem. |
-2 | Internal memory initialization problem. |
Characteristics and Limitations
Amplitude of output signals: The major limitation of the block in choice of amplitudes is imposed by the analog card; it is limited to +/- 16 V. Thus the user should consider this limiting resource in the choice of gain, amplitude and offset.
Direct Feedthrough | No |
---|---|
Discrete sample time | Inherited |
XHP support | Yes |
Work offline | No |