SCHEMATIC EDITOR WORKFLOW
eHS licence class is counted over 5 different kind of criteria.
Number of Switches
Number of sources
Number of outputs
Number of non-linear components
Note: Some high level components, such as machines, contains sources, outputs and switches
For readability purpose, 0 values are not mentioned.
Component | Switch | Source | Output 1 | Passive / Non-Linear | States | |
---|---|---|---|---|---|---|
| 1 | None | ||||
| 1 | None | ||||
| None | |||||
| 1 | None | ||||
| 2 | None | ||||
| 1 | 1 | 1 | None | ||
| 1 | None | ||||
Half-Bridge converter | 2 | None | ||||
3-Level NPC Arm | 4 | None | ||||
3-Level T-Type Arm | 4 | None (eHS Gen5 Specific) | ||||
Single Phase Cycloconverter | 8 | None (eHS Gen5 Specific) | ||||
Single Phase Ideal Two Winding Transformer | 3 | None | ||||
Single Phase Ideal Three Winding Transformer | 4 | None | ||||
Single Phase Ideal Two Winding Mutual Inductance | 2 | None | ||||
Three Winding Mutual Inductance | 3 | None | ||||
Saturable Transformer | 1 | 1 | 3 | None | ||
| 2 | 3 | 3 |
| ||
| 2 | 3 | 3 |
| ||
| 4 | 6 | 6 |
| ||
Pi Section Line | 2 X NBSECTION +1 | None | ||||
FD Line 1 Phase | 2 | XSG_FDLINE | ||||
FD Line 2 Phase | 4 | XSG_FDLINE | ||||
FD Line 3 Phase | 6 | XSG_FDLINE | ||||
FD Line 4 Phase | 8 | XSG_FDLINE | ||||
FD Line 6 Phase | 12 | XSG_FDLINE | ||||
FD Line 12 Phase | 24 | XSG_FDLINE | ||||
Stubline | 1 | 1 | None | |||
| 2 | HIGH_PERFORMANCE | ||||
| 4 | HIGH_PERFORMANCE | ||||
| 6 | HIGH_PERFORMANCE |