The “Line Data Report” window display a report of the transmission line models.
Functions with right mouse button in line data window:

Print the Geometrical / Electrical parametersPrint the Geometrical and Electrical parameters in the Line Data Report.
Save the Line Data Report in a fileSave the Line Data Report in a text file.
Clear the Line Data ReportClear the current data in the Line Data Report.

HYPERSIM LINE

The “Hypersim Line” window also allows you to download parameters into Hypersim Line models.
Apply the parameters to the Hypersim Line models that you have selected.

Example of a 735-kV three-phase line transposed.
Check the figure 7.1 for the geometrical parameters of the line and 7.3 for the layout of conductor.



--------------------------------------------------------------------------------
Hyperline Report Thu Oct 26 10:42:41 EDT 2006
--------------------------------------------------------------------------------
COMMENTS:
Example of a 735-kV three-phase line
Three bundles of 4 Bersfort ACSR 1355 MCM conductors
Two 1/2 inch-diameter steel ground wires
Ytower and Ymin are the average heights of conductors
LINE GEOMETRY:
Frequency (Hz): 60.0
Ground resistivity (m): 100.0
Number of phase conductors (bundles): 3
Number of ground wires (bundles): 2
------------------------------------------------------------------------
Conductor Phase X Y Tower Y Min Conductor
(bundle) Number (meters) (meters) (meters) Type
------------------------------------------------------------------------
p1 1 -12.80160 20.72640 20.72640 1
p2 2 0.00000 20.72640 20.72640 1
p3 3 12.80160 20.72640 20.72640 1
g1 0 -8.99160 32.91840 32.91840 2
g2 0 8.99160 32.91840 32.91840 2
------------------------------------------------------------------------
CONDUCTOR AND BUNDLE CHARACTERISTICS:
Number of conductor types or bundle types: 2
Transposition Options: Continuously transposed
Conductor internal inductance evaluated from: T/D Ratio
Include conductor skin effect: true
------------------------------------------------------------------------------------------------
Conductor Outside DC Relative Conductors Bundle Angle
Type Diameter T/D Ratio GMR Resistance Permeability Per Bundle Diameter Conductor 1
(cm) (cm) (/km) (cm) (degrees)
------------------------------------------------------------------------------------------------
1 3.55600 0.37500 0.00000000 0.04304860 1.00000 4 64.65824 45.00
2 1.27000 0.50000 0.00000000 3.10685596 1.00000 1 0.00000 0.00
------------------------------------------------------------------------------------------------

LINE PARAMETERS:


Resistance matrix (ohm/km):
107.09674E-03 97.2877E-03 94.985047E-03
97.2877E-03 110.49421E-03 97.2877E-03
94.985047E-03 97.2877E-03 107.09674E-03
Inductance matrix (H/km):
1.5767237E-03 751.60456E-06 616.2754E-06
751.60456E-06 1.5708172E-03 751.60456E-06
616.2754E-06 751.60456E-06 1.5767237E-03
Capacitance matrix (F/km):
11.661244E-09 -2.1267491E-09 -583.59054E-12
-2.1267491E-09 12.117359E-09 -2.1267491E-09
-583.59054E-12 -2.1267491E-09 11.661244E-09
Modal parameters for: Untransposed
Transformation matrix:
595.18244E-03 -707.10678E-03 -413.16278E-03
539.92049E-03 -20.667491E-15 811.53708E-03
595.18244E-03 707.10678E-03 -413.16278E-03
Modal resistances [0 1 2 3 ... N] (ohm/km)
300.43664E-03 12.111697E-03 11.281839E-03
Modal inductances [0 1 2 3 ... N] (H/km)
2.9777393E-03 960.44826E-06 775.19202E-06
Modal capacitances [0 1 2 3 ... N] (F/km)
8.580247E-09 12.244834E-09 14.548002E-09
Self impedance (Zero-sequence & Positive-sequence):
Line 1
[R0 R1] = 301.26953E-03 11.709084E-03 (ohm/km)
[L0 L1] = 2.9877445E-03 868.26E-06 (H/km)
[C0 C1] = 8.5885563E-09 13.425645E-09 (F/km)

REFERENCES

[1] HYPERSIM Reference guide manual for software version 9.1.
[2] Dommel, H., et al., Electromagnetic Transients Program Reference Manual (EMTP Theory Book), 1986.
[3] Carson, J. R., "Wave Propagation in Overhead Wires with Ground Return," Bell Systems Technical Journal, Vol. 5, pp 539-554, 1926.