Library
rtlab/Monitoring
Block
The OpSnapshot block allows users to take a snapshot when triggered by a specific signal.
Mask
Description
The OpSnapshot block is used to take a snapshot when triggered by a specific signal. This feature allows users to take a snapshot once a certain threshold is reached, which makes it possible to obtain information about a specified part of the real-time simulation. It is also possible to specify the slope (Rising or Falling) on which the threshold is crossed.
Parameters
Slope | Specifies the derivative on which the threshold level must be crossed for a snapshot to be taken. |
---|---|
| |
FileName: | Not available in the current version. By default, RT-LAB uses the model name with a suffix. |
Overwrite | If checked, it overwrites the previous snapshot file if one exist. If not checked, the block adds a different index number at the end of the filename for each snapshot taken. |
Inputs
Trigger | Signal that triggers a take of a snaphot when a specified level is reached. |
---|---|
Trig_level | Specifies the value that must be reached by the signal connected to the OpSnapshot input to trig a take of a snaphot. |
Outputs
This block has no outputs.
Characteristics and Limitations
Direct Feedthrough | Yes |
---|---|
Discrete sample time | No |
XHP support | Yes (Partial XHP only) |
Work offline | No |